Inspection Detail
Inspection: 123810996 - Duncan Machinery Movers, Inc.
Inspection Information - Office: Ky Labor Cabinet Division Of Osh Compliance
Site Address:
Duncan Machinery Movers, Inc.
Green Gate Farm, Iron Works Road
Lexington, KY 40511
Mailing Address:
P. O. Box 12290, Lexington, KY 40582
Union Status: Union
SIC:1796
NAICS: 0
Inspection Type: Accident
Scope: Partial
Advanced Notice: N
Ownership: Private
Safety/Health: Safety
Close Conference: 05/07/1993
Planning Guide: Safety-Construction
Emphasis:
Case Closed: 02/23/1994
Type | Activity Nr | Safety | Health |
---|---|---|---|
Accident | 360208912 |
Violations/Penalties | Serious | Willful | Repeat | Other | Unclass | Total |
---|---|---|---|---|---|---|
Initial Violations | 1 | 2 | 3 | |||
Current Violations | 1 | 2 | 3 | |||
Initial Penalty | $3,500 | $0 | $0 | $0 | $0 | $3,500 |
Current Penalty | $3,500 | $0 | $0 | $0 | $0 | $3,500 |
FTA Penalty | $0 | $0 | $0 | $0 | $0 | $0 |
# | Citation ID | Citaton Type | Standard Cited | Issuance Date | Abatement Due Date | Current Penalty | Initial Penalty | FTA Penalty | Contest | Latest Event | Note |
---|---|---|---|---|---|---|---|---|---|---|---|
1. | 01001 | Serious | 19260550 A15 I | 06/11/1993 | 04/23/1993 | $3,500 | $3,500 | $0 | 06/24/1993 | R - Review Commission | |
2. | 02001 | Other | 19100147 C04 I | 06/11/1993 | 07/22/1993 | $0 | $0 | $0 | 06/24/1993 | R - Review Commission | |
3. | 02002 | Other | 19101200 E01 | 06/11/1993 | 07/22/1993 | $0 | $0 | $0 | 06/24/1993 | R - Review Commission |
Investigation Summary
AN EMPLOYEE WAS CLIMBING ONTO A COMPANY TRUCK TO ATTACH A LOAD ON THE TRUCK TO THE LOAD LINE OF A HYDRAULIC TRUCK CRANE. THE LOAD LINE CONTACTED A 7200-VOLT OVERHEAD POWER LINE, AND THE EMPLOYEE WAS ELECTROCUTED.
Keywords: OVERHEAD POWER LINE, ELECTRICAL, E GI IA, ELECTROCUTED, LOAD LINE, CRANE
# | Inspection | Age | Sex | Degree of Injury | Nature of Injury | Occupation |
---|---|---|---|---|---|---|
1 | 123810996 | Occupation Not Listed |