Inspection Detail
Inspection: 123788531 - Littleford-Day, Incorporated
Inspection Information - Office: Ky Labor Cabinet Division Of Osh Compliance
Site Address:
Littleford-Day, Incorporated
7451 Empire Drive
Florence, KY 41042
Mailing Address:
, , 00000
Union Status: Union
SIC:3556
NAICS: 0
Inspection Type: Accident
Scope: Partial
Advanced Notice: N
Ownership: Private
Safety/Health: Safety
Close Conference: 07/21/1994
Planning Guide: Safety-Manufacturing
Emphasis:
Case Closed: 02/07/1996
| Type | Activity Nr | Safety | Health |
|---|---|---|---|
| Accident | 361314750 |
| Violations/Penalties | Serious | Willful | Repeat | Other | Unclass | Total |
|---|---|---|---|---|---|---|
| Initial Violations | 2 | 2 | ||||
| Current Violations | 2 | 2 | ||||
| Initial Penalty | $4,500 | $0 | $0 | $0 | $0 | $4,500 |
| Current Penalty | $3,050 | $0 | $0 | $0 | $0 | $3,050 |
| FTA Penalty | $0 | $0 | $0 | $0 | $0 | $0 |
| # | Citation ID | Citaton Type | Standard Cited | Issuance Date | Abatement Due Date | Current Penalty | Initial Penalty | FTA Penalty | Contest | Latest Event | Note |
|---|---|---|---|---|---|---|---|---|---|---|---|
| 1. | 01001A | Serious | 338003101 A | 08/24/1994 | 09/20/1994 | $1,525 | $3,000 | $0 | 09/15/1994 | R - Review Commission | |
| 2. | 01001B | Serious | 19100147 C01 | 08/24/1994 | 09/20/1994 | $0 | $0 | $0 | 09/15/1994 | R - Review Commission | |
| 3. | 01002A | Serious | 19101030 C01 I | 08/24/1994 | 10/04/1994 | $1,525 | $1,500 | $0 | 09/15/1994 | R - Review Commission | |
| 4. | 01002B | Serious | 19101030 D01 | 08/24/1994 | 10/04/1994 | $0 | $0 | $0 | 09/15/1994 | R - Review Commission | |
| 5. | 01002C | Serious | 19101030 G02 IIA | 08/24/1994 | 10/04/1994 | $0 | $0 | $0 | 09/15/1994 | R - Review Commission |
Investigation Summary
An assembler was manufacturing an industrial mixer. He had his head inside the mixer, checking to see if the batch release door was flush. Apparently, he meant to press the "discharge open" button to open the door he was checking. This button was next to the start button for the mixer. The employee pressed the start button by mistake; and the mixer started up, decapitating the employee. An interlock switch had been installed to prevent the mixer from starting with the side door open. Unfortunately, it malfunctioned.
Keywords: START BUTTON, MIXER, INTERLOCK, LOCKOUT
| # | Inspection | Age | Sex | Degree of Injury | Nature of Injury | Occupation |
|---|---|---|---|---|---|---|
| 1 | 123788531 | Fatality | Amputation | Assemblers |
Translate