Powered by GoogleTranslate

Inspection Detail

Inspection: 123759383 - Fine Line Communications

Inspection Information - Office: Or-E-Salem 1054100

 

Inspection Nr: 123759383
Report ID: 1054113
Date Opened: 03/24/1993

Site Address:
Fine Line Communications
4230 Logsden Rd
Siletz, OR 97380

Mailing Address:
1358 Quaker St, Eugene, OR 97402

Union Status: NonUnion

SIC:1623

NAICS: 0 


Inspection Type: Accident

Scope: Partial

Advanced Notice: N

Ownership: Private

Safety/Health: Safety

Close Conference: 03/24/1993

Planning Guide: Safety-Construction

Emphasis:

Case Closed: 08/18/2003


Violation Summary
Violations/Penalties Serious Willful Repeat Other Unclass Total
Initial Violations 6 6
Current Violations 3 3
Initial Penalty $13,900 $0 $0 $0 $0 $13,900
Current Penalty $5,880 $0 $0 $0 $0 $5,880
FTA Penalty $0 $0 $0 $0 $0 $0

Violation Items
# Citation ID Citation Type Standard Cited Issuance Date Abatement Due Date Current Penalty Initial Penalty FTA Penalty Contest Latest Event Note
1. 01001 Serious 7820043 06/01/1993 05/17/1993 $0 $5,000 $0 06/18/1993 J - ALJ Decision Citation has been deleted.
2. 01002 Serious 7820379 06/01/1993 06/04/1993 $1,750 $2,500 $0 06/18/1993 J - ALJ Decision  
3. 01003 Serious 782004901 06/01/1993 06/08/1993 $3,500 $5,000 $0 06/18/1993 J - ALJ Decision  
4. 01004 Serious 782004904 B 06/01/1993 05/17/1993 $0 $200 $0 06/18/1993 J - ALJ Decision Citation has been deleted.
5. 01005 Serious 782004904 C 06/01/1993 06/08/1993 $0 $300 $0 06/18/1993 J - ALJ Decision Citation has been deleted.
6. 01006 Serious 782028701 06/01/1993 06/04/1993 $630 $900 $0 06/18/1993 J - ALJ Decision  

Investigation Summary

Investigation Nr: 170129951
Event: 03/24/1993
ELECTRIC SHOCK - CONTACT WITH OVERHEAD LINE THRU METAL TAPE

A CABLE TELEVISION LINE WORKER, ACTING AS THE FOREMAN OF HIS CREW, WAS WORKING FROM AN AERIAL LIFT. THE CREW WAS STRINGING MESSENGER CABLE, ATTACHING IT TO UTILITY POLES AT A POINT 40 INCHES BELOW EXISTING OVERHEAD POWER LINES. TWO CREW MEMBERS WERE FLAGGING TRAFFIC, AND ANOTHER CREW MEMBER WAS ON THE GROUND ASSISTING THE FOREMAN. THE FOREMAN WAS USING A METAL MEASURING TAPE TO MEASURE THE DISTANCE DOWN ALONG THE POLE FROM THE CROSSARM CARRYING THE OVERHEAD POWER LINES. THE MEASURING TAPE CONTACTED A FUSED CUTOUT FOR A TAP LINE LEADING TO A NEARBY RESIDENCE. THE CURRENT PASSED THROUGH THE METAL TAPE TO THE MESSENGER CABLE, WHICH WAS DRAPED ACROSS THE FOREMAN'S ARM, AND THEN TO GROUND. THE CURRENT ENTERED AND EXITED THE EMPLOYEE'S BODY AT HIS RIGHT WRIST, WHICH WAS TOUCHING THE METAL TAPE, AND THE RIGHT SIDE OF HIS CHEST, WHICH WAS APPARENTLY TOUCHING THE MESSENGER CABLE. THE CUTOUT OPENED TO STOP THE CURRENT FLOW. THE FOREMAN DROPPED THE CABLE AND WAS IN A SEMI-CONSCIOUS STATE AS HIS COWORKER LOWERED THE AERIAL LIFT. FIRST AID WAS ADMINISTERED BY A NEARBY NEIGHBOR UNTIL EMERGENCY MEDICAL ASSISTANCE ARRIVED. THE EMPLOYEE WAS TRANSPORTED TO A HOSPITAL, WHERE HE WAS TREATED AND HELD OVERNIGHT FOR OBSERVATION. HE RECEIVED BURNS ON BOTH HANDS AND ON HIS CHEST. THERE HAD BEEN INADEQUATE TRAINING AND SUPERVISION OF EMPLOYEES ON THIS CREW.

Keywords: BURN, CHEST, OVERHEAD POWER LINE, ELECTRICAL, MEASURING DEVICE, E GI IA, ELECTRIC SHOCK, UNTRAINED, HAND

Investigated Inspection
# Inspection Age Sex Degree of Injury Nature of Injury Occupation
1 123759383 Hospitalized injury Electric Shock Misc. electrical & electronic equipment repairers
Back to Top

Thank You for Visiting Our Website

You are exiting the Department of Labor's Web server.

The Department of Labor does not endorse, takes no responsibility for, and exercises no control over the linked organization or its views, or contents, nor does it vouch for the accuracy or accessibility of the information contained on the destination server. The Department of Labor also cannot authorize the use of copyrighted materials contained in linked Web sites. Users must request such authorization from the sponsor of the linked Web site. Thank you for visiting our site. Please click the button below to continue.