Powered by GoogleTranslate

Inspection Detail

Inspection: 123751679 - Weyerhaeuser Co

Inspection Information - Office: Or-E-Salem 1054100

 

Inspection Nr: 123751679
Report ID: 1054118
Date Opened: 01/03/1996

Site Address:
Weyerhaeuser Co
6400 Ashland Hwy Hwy 66
Klamath Falls, OR 97601

Mailing Address:
Po Box 9, Klamath Falls, OR 97601

Union Status: Union

SIC:5113

NAICS: 0 


Inspection Type: Accident

Scope: Partial

Advanced Notice: N

Ownership: Private

Safety/Health: Safety

Close Conference: 02/20/1996

Planning Guide: Safety-Manufacturing

Emphasis:

Case Closed: 06/18/1998


Violation Summary
Violations/Penalties Serious Willful Repeat Other Unclass Total
Initial Violations 2 2
Current Violations 2 2
Initial Penalty $6,250 $0 $0 $0 $0 $6,250
Current Penalty $4,375 $0 $0 $0 $0 $4,375
FTA Penalty $0 $0 $0 $0 $0 $0

Violation Items
# Citation ID Citaton Type Standard Cited Issuance Date Abatement Due Date Current Penalty Initial Penalty FTA Penalty Contest Latest Event Note
1. 01001 Serious 701076001 A 03/14/1996 03/19/1996 $875 $1,250 $0 03/26/1996 L - State Settlement  
2. 01002 Serious 19100156 C01 03/14/1996 04/16/1996 $3,500 $5,000 $0 03/26/1996 L - State Settlement  

Investigation Summary

Investigation Nr: 170743280
Event: 01/03/1996
Two employees burned by fireball

At 11:50 p.m. on January 1, 1996, Employees #1 and #2, pipefitters for Weyerhaeuser Co., were ventilating a compressor at the hardwood mill. Shortly before, a small fire had started on one of the air line valves about 8 ft to 10 ft away from the air compressor. The fire had already been extinguished and the employees were opening the doors to assess the damage to the compressor room. As they were in the room, two fireballs were emitted from the heat exchanging unit of the compressor, severely burning both employees. They were hospitalized.

Keywords: BURN, COMPRESSOR, FIRE, VALVE

Investigated Inspection
# Inspection Age Sex Degree of Injury Nature of Injury Occupation
1 123751679 Hospitalized injury Burn/Scald(Heat) Plumbers, pipefitters and steamfitters
2 123751679 Hospitalized injury Burn/Scald(Heat) Plumbers, pipefitters and steamfitters
Back to Top

Thank You for Visiting Our Website

You are exiting the Department of Labor's Web server.

The Department of Labor does not endorse, takes no responsibility for, and exercises no control over the linked organization or its views, or contents, nor does it vouch for the accuracy or accessibility of the information contained on the destination server. The Department of Labor also cannot authorize the use of copyrighted materials contained in linked Web sites. Users must request such authorization from the sponsor of the linked Web site. Thank you for visiting our site. Please click the button below to continue.