Powered by GoogleTranslate

Inspection Detail

Inspection: 123751042 - Ekman Enterprises Inc

Inspection Information - Office: Or-E-Salem 1054100

 

Inspection Nr: 123751042
Report ID: 1054118
Date Opened: 09/01/1993

Site Address:
Ekman Enterprises Inc
3205 6th St
Klamath Falls, OR 97601

Mailing Address:
, , 00000

Union Status: NonUnion

SIC:1521

NAICS: 0 


Inspection Type: Accident

Scope: Complete

Advanced Notice: N

Ownership: Private

Safety/Health: Safety

Close Conference: 09/01/1993

Planning Guide: Safety-Construction

Emphasis:

Case Closed: 12/07/2001


Related Activity
Type Activity Nr Safety Health
Accident 362316184
Violation Summary
Violations/Penalties Serious Willful Repeat Other Unclass Total
Initial Violations 2 1 1 4
Current Violations 2 1 1 4
Initial Penalty $10,000 $50,000 $0 $100 $0 $60,100
Current Penalty $8,000 $41,925 $0 $75 $0 $50,000
FTA Penalty $0 $0 $0 $0 $0 $0

Violation Items
# Citation ID Citaton Type Standard Cited Issuance Date Abatement Due Date Current Penalty Initial Penalty FTA Penalty Contest Latest Event Note
1. 01001 Serious 703004704 A 01/10/1994 01/13/1994 $4,000 $5,000 $0 01/14/1994 L - State Settlement  
2. 01002 Serious 19260021 B02 01/10/1994 01/13/1994 $4,000 $5,000 $0 01/14/1994 L - State Settlement  
3. 02003 Willful 703004701 01/10/1994 01/13/1994 $41,925 $50,000 $0 01/14/1994 L - State Settlement  
4. 03004 Other 740004502 B 01/10/1994 01/13/1994 $75 $100 $0 A - Amendment  

Investigation Summary

Investigation Nr: 170133482
Event: 08/31/1993
ELECTRIC SHOCK - DIRECT CONTACT WITH OVERHEAD LINE

Two roofers were in an aerial lift, working on the edge of a roof at an apartment building. As they were working, the roofer who was operating the aerial lift contacted a 12-kilovolt overhead power line. This energized the aerial lift's metal platform. One of the employees was electrocuted; the other received an electric shock and was seriously injured. The injured employee was hospitalized.

Keywords: E GI III, OVERHEAD POWER LINE, ELECTRICAL, ELECTROCUTED, ROOFER, ELECTRIC SHOCK, UNTRAINED, AERIAL LIFT

Investigated Inspection
# Inspection Age Sex Degree of Injury Nature of Injury Occupation
1 123751042 Fatality Electric Shock Roofers
2 123751042 Hospitalized injury Electric Shock Roofers
Back to Top

Thank You for Visiting Our Website

You are exiting the Department of Labor's Web server.

The Department of Labor does not endorse, takes no responsibility for, and exercises no control over the linked organization or its views, or contents, nor does it vouch for the accuracy or accessibility of the information contained on the destination server. The Department of Labor also cannot authorize the use of copyrighted materials contained in linked Web sites. Users must request such authorization from the sponsor of the linked Web site. Thank you for visiting our site. Please click the button below to continue.