Inspection Detail
Inspection: 123726978 - Sach Mikami General Partner
Inspection Information - Office: Or-E-Salem 1054100
Site Address:
Sach Mikami General Partner
Hinkle Rd - Experimental Station
Hermiston, OR 97838
Mailing Address:
P O Box 780, Hermiston, OR 97838
Union Status: NonUnion
SIC:0191
NAICS: 0
Inspection Type: Accident
Scope: Partial
Advanced Notice: N
Ownership: Private
Safety/Health: Safety
Close Conference: 04/15/1994
Planning Guide: Safety-Manufacturing
Emphasis:
Case Closed: 04/15/1994
Investigation Summary
Employee #1 was helping a coworker repair an incline conveyor. While the coworker jacked up the conveyor in order to weld leg extensions onto it, Employee #1 placed a block of wood under the next set of legs to be repaired. The conveyor slipped off the jack and the legs came down on the block, severing two of Employee #1's fingertips.
Keywords: SEVERED, REPAIR, AGRICULTURE, FINGER, WORK RULES, CONVEYOR
| # | Inspection | Age | Sex | Degree of Injury | Nature of Injury | Occupation |
|---|---|---|---|---|---|---|
| 1 | 123726978 | Hospitalized injury | Amputation | Farmers, except horticultural |