Powered by GoogleTranslate

Inspection Detail

Inspection: 123663775 - W.W. Enroughty & Son Inc.

Inspection Information - Office: Va-E-Richmond (Regional Office) - Safety 0355111

 

Inspection Nr: 123663775
Report ID: 0355111
Date Opened: 04/26/1994

Site Address:
W.W. Enroughty & Son Inc.
11100 W. Broad St.
Glen Allen, VA 23060

Mailing Address:
P.O. Box 6383, Ashland, VA 23005

Union Status: NonUnion

SIC:1721

NAICS: 0 


Inspection Type: Accident

Scope: Partial

Advanced Notice: N

Ownership: Private

Safety/Health: Safety

Close Conference: 10/20/1994

Planning Guide: Safety-Construction

Emphasis:

Case Closed: 07/26/1999


Related Activity
Type Activity Nr Safety Health
Accident 360300255
Violation Summary
Violations/Penalties Serious Willful Repeat Other Unclass Total
Initial Violations 2 2
Current Violations 1 1
Initial Penalty $0 $120,000 $0 $0 $0 $120,000
Current Penalty $3,000 $0 $0 $0 $0 $3,000
FTA Penalty $0 $0 $0 $0 $0 $0

Violation Items
# Citation ID Citaton Type Standard Cited Issuance Date Abatement Due Date Current Penalty Initial Penalty FTA Penalty Contest Latest Event Note
1. 01001 Willful 510001 A 10/21/1994 10/25/1994 $70,000 $70,000 $0 11/04/1994 1 - State Lower Court Citation has been deleted.
2. 01002 Serious 19260556 B02 10/21/1994 10/25/1994 $3,000 $50,000 $0 11/04/1994 1 - State Lower Court  

Investigation Summary

Investigation Nr: 14444855
Event: 04/26/1994
One employee dies, another injured when lift tips over

At approximately 11:15 a.m. on April 26, 1994, Employees #1 and #2 were elevating a Marklift 100 aerial lift after stocking their paint supplies. The operator raised the aerial lift above the angle the machine limit switch would allow and extended the 100 ft boom to its maximum length. When the operator began to lower the basket and swing the lift toward a two-story building, the lift tipped over. The two employees were seriously injured: Employee #1 died of massive head injuries on April 30, 1994. The investigation revealed that, although the boom had been fully extended before reaching the required 55 degree angle, the employees had been operating the machine within the guidelines established by the manufacturer. The accident was the result of equipment failure. The limit switches on the lift did not prevent the boom from extending too far before reaching the required 55 degree angle.

Keywords: HEAD, BOOM, WORK RULES, CONSTRUCTION, EQUIPMENT FAILURE, AERIAL LIFT, OVERTURN

Investigated Inspection
# Inspection Age Sex Degree of Injury Nature of Injury Occupation
1 123663775 Fatality Concussion Mechanical controls and valve repairers
2 123663775 Hospitalized injury Fracture Mechanical controls and valve repairers
Back to Top

Thank You for Visiting Our Website

You are exiting the Department of Labor's Web server.

The Department of Labor does not endorse, takes no responsibility for, and exercises no control over the linked organization or its views, or contents, nor does it vouch for the accuracy or accessibility of the information contained on the destination server. The Department of Labor also cannot authorize the use of copyrighted materials contained in linked Web sites. Users must request such authorization from the sponsor of the linked Web site. Thank you for visiting our site. Please click the button below to continue.

Close