Powered by GoogleTranslate

Inspection Detail

Inspection: 123622094 - Mobile Factory Outlet, Inc.

Inspection Information - Office: Houston South Area Office

 

Inspection Nr: 123622094
Report ID: 0626700
Date Opened: 08/19/1998

Site Address:
Mobile Factory Outlet, Inc.
1925 First St.
Rosenberg, TX 77471

Mailing Address:
, , 00000

Union Status: NonUnion

SIC:5271

NAICS: 0 


Inspection Type: Accident

Scope: Partial

Advanced Notice: N

Ownership: Private

Safety/Health: Safety

Close Conference: 08/19/1998

Emphasis:

Case Closed: 03/11/1999


Related Activity
Type Activity Nr Safety Health
Accident 360974539
Violation Summary
Violations/Penalties Serious Willful Repeat Other Unclass Total
Initial Violations 5 5
Current Violations 5 5
Initial Penalty $10,500 $0 $0 $0 $0 $10,500
Current Penalty $8,400 $0 $0 $0 $0 $8,400
FTA Penalty $0 $0 $0 $0 $0 $0

Violation Items
# Citation ID Citaton Type Standard Cited Issuance Date Abatement Due Date Current Penalty Initial Penalty FTA Penalty Contest Latest Event Note
1. 01001 Serious 19100303 B02 12/15/1998 02/03/1999 $2,100 $2,100 $0 I - Informal Settlement  
2. 01002 Serious 19100303 F 12/15/1998 02/03/1999 $2,100 $2,100 $0 I - Informal Settlement  
3. 01003 Serious 19100304 F01 IVC 12/15/1998 02/03/1999 $2,100 $2,100 $0 I - Informal Settlement  
4. 01004 Serious 19100305 A02 IIIG 12/15/1998 02/03/1999 $0 $2,100 $0 I - Informal Settlement  
5. 01005 Serious 19100305 B02 12/15/1998 02/03/1999 $2,100 $2,100 $0 I - Informal Settlement  

Investigation Summary

Investigation Nr: 14411250
Event: 08/17/1998
ELECTRIC SHOCK - APPARENT GROUND FAULT IN MANUFACTURED HOME

A 37-year-old employee was installing a heating and air conditioning crossover duct on the underside of a manufactured home. Coworkers found the employee dead, lying on the ground on copper tubing, which ran to the air conditioner condenser. He had apparently been electrocuted. The manufactured home was not grounded.

Keywords: DUCT, ELECTRICAL, E GI VII, ELECTROCUTED, GROUND FAULT, EQUIPMENT GROUNDING

Investigated Inspection
# Inspection Age Sex Degree of Injury Nature of Injury Occupation
1 123622094 Fatality Electric Shock Occupation not reported
Back to Top

Thank You for Visiting Our Website

You are exiting the Department of Labor's Web server.

The Department of Labor does not endorse, takes no responsibility for, and exercises no control over the linked organization or its views, or contents, nor does it vouch for the accuracy or accessibility of the information contained on the destination server. The Department of Labor also cannot authorize the use of copyrighted materials contained in linked Web sites. Users must request such authorization from the sponsor of the linked Web site. Thank you for visiting our site. Please click the button below to continue.