Inspection Detail
Inspection: 123618779 - Omega Environmental, Inc.
Inspection Information - Office: Houston South Area Office
Site Address:
Omega Environmental, Inc.
6101 Stewart Rd.
Galveston, TX 77551
Mailing Address:
3355 West 11th Street, Houston, TX 77008
Union Status: NonUnion
SIC:1799
NAICS: 0
Inspection Type: Accident
Scope: Partial
Advanced Notice: Y
Ownership: Private
Safety/Health: Safety
Close Conference: 11/02/1998
Planning Guide: Safety-Manufacturing
Emphasis:
Case Closed: 03/14/2000
| Type | Activity Nr | Safety | Health |
|---|---|---|---|
| Accident | 360974653 |
| Violations/Penalties | Serious | Willful | Repeat | Other | Unclass | Total |
|---|---|---|---|---|---|---|
| Initial Violations | 4 | 4 | ||||
| Current Violations | 1 | 1 | ||||
| Initial Penalty | $28,000 | $0 | $0 | $0 | $0 | $28,000 |
| Current Penalty | $7,000 | $0 | $0 | $0 | $0 | $7,000 |
| FTA Penalty | $0 | $0 | $0 | $0 | $0 | $0 |
| # | Citation ID | Citaton Type | Standard Cited | Issuance Date | Abatement Due Date | Current Penalty | Initial Penalty | FTA Penalty | Contest | Latest Event | Note |
|---|---|---|---|---|---|---|---|---|---|---|---|
| 1. | 01001 | Serious | 19100147 C06 I | 02/02/1999 | 02/08/1999 | $7,000 | $7,000 | $0 | 03/01/1999 | J - ALJ Decision | |
| 2. | 01002 | Serious | 19100147 C07 I | 02/02/1999 | 02/08/1999 | $0 | $7,000 | $0 | 03/01/1999 | J - ALJ Decision | Citation has been deleted. |
| 3. | 01003 | Serious | 19100147 D04 I | 02/02/1999 | 02/08/1999 | $0 | $7,000 | $0 | 03/01/1999 | J - ALJ Decision | Citation has been deleted. |
| 4. | 01004 | Serious | 19100147 D05 I | 02/02/1999 | 02/08/1999 | $0 | $7,000 | $0 | 03/01/1999 | J - ALJ Decision | Citation has been deleted. |
Investigation Summary
An employee was servicing a sump pump on a premium gasoline tank at a gasoline station. He was placing the cover on a housing for a 480-volt capacitor. The housing did not fit the capacitor properly, and the capacitor fell against the housing wall with its terminals touching the housing. When the employee placed one hand on the housing and the other hand on the metal ring of the manhole opening, he was electrocuted. Electrical burns were found on his hands and evidence of electric arcing was found on the capacitor terminals and the inside of the housing.
Keywords: E GI IV, ELECTRICAL, ELECTROCUTED, CAPACITOR, LOCKOUT, MECH MALFUNCTION
| # | Inspection | Age | Sex | Degree of Injury | Nature of Injury | Occupation |
|---|---|---|---|---|---|---|
| 1 | 123618779 | Fatality | Electric Shock | Occupation not reported |