Inspection Detail
Inspection: 123589368 - Ideal Poultry Breeding Farms, Inc.
Inspection Information - Office: Austin Area Office
Site Address:
Ideal Poultry Breeding Farms, Inc.
215 W. Main
Cameron, TX 76520
Mailing Address:
P. O. Box 591, Cameron, TX 76520
Union Status: NonUnion
SIC:0254
NAICS: 0
Inspection Type: Accident
Scope: Partial
Advanced Notice: N
Ownership: Private
Safety/Health: Safety
Close Conference: 12/20/1994
Emphasis:
Case Closed: 02/06/1995
Type | Activity Nr | Safety | Health |
---|---|---|---|
Accident | 360906135 |
Violations/Penalties | Serious | Willful | Repeat | Other | Unclass | Total |
---|---|---|---|---|---|---|
Initial Violations | 2 | 1 | 3 | |||
Current Violations | 1 | 2 | 3 | |||
Initial Penalty | $3,000 | $0 | $0 | $1,500 | $0 | $4,500 |
Current Penalty | $750 | $0 | $0 | $250 | $0 | $1,000 |
FTA Penalty | $0 | $0 | $0 | $0 | $0 | $0 |
# | Citation ID | Citaton Type | Standard Cited | Issuance Date | Abatement Due Date | Current Penalty | Initial Penalty | FTA Penalty | Contest | Latest Event | Note |
---|---|---|---|---|---|---|---|---|---|---|---|
1. | 01001 | Serious | 19100304 D02 II | 01/18/1995 | 01/26/1995 | $750 | $1,500 | $0 | I - Informal Settlement | ||
2. | 01002A | Serious | 19100333 A | 01/18/1995 | 01/26/1995 | $1,500 | $1,500 | $0 | I - Informal Settlement | Citation has been deleted. | |
3. | 01002B | Other | 19100333 B02 I | 01/18/1995 | 02/13/1995 | $250 | $0 | $0 | I - Informal Settlement | ||
4. | 02001 | Other | 19040008 | 01/18/1995 | 01/23/1995 | $0 | $1,500 | $0 | I - Informal Settlement |
Investigation Summary
An employee was working on the roof of a building. He contacted an overhead power line that was located 30.625 inches away from his working position and was electrocuted. (He also fell from the roof to the ground, a distance of about 40 feet.)
Keywords: E GI III, OVERHEAD POWER LINE, ROOF, ELECTRICAL, ELECTROCUTED
# | Inspection | Age | Sex | Degree of Injury | Nature of Injury | Occupation |
---|---|---|---|---|---|---|
1 | 123589368 | Fatality | Electric Shock | Occupation not reported |