Powered by GoogleTranslate

Inspection Detail

Inspection: 123570202 - International Cylinder Manufacturing Inc

Inspection Information - Office: Houston South Area Office

 

Inspection Nr: 123570202
Report ID: 0626700
Date Opened: 03/13/1997

Site Address:
International Cylinder Manufacturing Inc
27711 Katy Freeway
Katy, TX 77494

Mailing Address:
, , 00000

Union Status: NonUnion

SIC:3593

NAICS: 0 


Inspection Type: Accident

Scope: Partial

Advanced Notice: N

Ownership: Private

Safety/Health: Safety

Close Conference: 03/14/1997

Planning Guide: Safety-Manufacturing

Emphasis:

Case Closed: 05/04/1998


Related Activity
Type Activity Nr Safety Health
Accident 361144116
Violation Summary
Violations/Penalties Serious Willful Repeat Other Unclass Total
Initial Violations 3 2 5
Current Violations 3 2 5
Initial Penalty $7,500 $0 $0 $800 $0 $8,300
Current Penalty $7,500 $0 $0 $0 $0 $7,500
FTA Penalty $0 $0 $0 $0 $0 $0

Violation Items
# Citation ID Citaton Type Standard Cited Issuance Date Abatement Due Date Current Penalty Initial Penalty FTA Penalty Contest Latest Event Note
1. 01001 Serious 19100147 C01 06/16/1997 07/19/1997 $2,500 $2,500 $0 I - Informal Settlement  
2. 01002 Serious 19100147 C01 06/16/1997 07/19/1997 $2,500 $2,500 $0 I - Informal Settlement  
3. 01003 Serious 19100147 C01 06/16/1997 07/19/1997 $2,500 $2,500 $0 I - Informal Settlement  
4. 02001 Other 19040008 06/16/1997 06/20/1997 $0 $500 $0 I - Informal Settlement  
5. 02002 Other 19101200 E01 06/16/1997 08/02/1997 $0 $300 $0 I - Informal Settlement  

Investigation Summary

Investigation Nr: 14408157
Event: 03/12/1997
Employee killed when struck by flying flange

On or about April 12, 1997, Employee #1 and a coworker were running a hydraulic pressure test procedure on a motion compensatory cylinder when the flange blew off. It struck Employee #1 in the head, killing him instantly. Approximately 10 bolts had been used to secure the 2.44-in.-thick flange to the cylinder, but the bolts had not been inspected to determine if they were the correct length to secure the part. The bolts were stripped away when the flange blew. The length of thread going into the flange head was 1.375 in. Eight of the 10 bolts were 2.75 in., 2.625 in., or 2.5 in.; the length of all bolts should have been approximately 3.81 in.

Keywords: HEAD, CYLINDER, UNSECURED, WORK RULES, STRUCK BY, FLYING OBJECT, OIL RIG

Investigated Inspection
# Inspection Age Sex Degree of Injury Nature of Injury Occupation
1 123570202 Fatality Other Occupation not reported
Back to Top

Thank You for Visiting Our Website

You are exiting the Department of Labor's Web server.

The Department of Labor does not endorse, takes no responsibility for, and exercises no control over the linked organization or its views, or contents, nor does it vouch for the accuracy or accessibility of the information contained on the destination server. The Department of Labor also cannot authorize the use of copyrighted materials contained in linked Web sites. Users must request such authorization from the sponsor of the linked Web site. Thank you for visiting our site. Please click the button below to continue.

Close