Inspection Detail
Inspection: 123551319 - Lacy Well Service, Inc.
Inspection Information - Office: Austin Area Office
Site Address:
Lacy Well Service, Inc.
Peach Creek Cutoff At Texas Hwy 6
College Station, TX 77840
Mailing Address:
Po Box 5639, Bryan, TX 77805
Union Status: NonUnion
SIC:1389
NAICS: 0
Inspection Type: Accident
Scope: Partial
Advanced Notice: N
Ownership: Private
Safety/Health: Safety
Close Conference: 06/08/1994
Emphasis:
Case Closed: 07/15/1994
Type | Activity Nr | Safety | Health |
---|---|---|---|
Accident | 361130677 |
Investigation Summary
Employee #1 was stacking tubing and a coworker, a derrick operator, was pulling tubing from an injection well. The tubing hung up on a blow out preventor ram, which was either entirely or partially closed. Before the coworker could shut the system down, the draw works pulled the top section of the telescoping mast down and Employee #1 was pulled 50 ft down with it. He died.
Keywords: JAMMED, DRAWWORKS, OIL RIG MAST, FALL, OIL WELL SERVICING
# | Inspection | Age | Sex | Degree of Injury | Nature of Injury | Occupation |
---|---|---|---|---|---|---|
1 | 123551319 | Fatality | Fracture | Occupation not reported |