Powered by GoogleTranslate

Inspection Detail

Inspection: 123551319 - Lacy Well Service, Inc.

Inspection Information - Office: Austin Area Office

 

Inspection Nr: 123551319
Report ID: 0625400
Date Opened: 06/07/1994

Site Address:
Lacy Well Service, Inc.
Peach Creek Cutoff At Texas Hwy 6
College Station, TX 77840

Mailing Address:
Po Box 5639, Bryan, TX 77805

Union Status: NonUnion

SIC:1389

NAICS: 0 


Inspection Type: Accident

Scope: Partial

Advanced Notice: N

Ownership: Private

Safety/Health: Safety

Close Conference: 06/08/1994

Emphasis:

Case Closed: 07/15/1994


Related Activity
Type Activity Nr Safety Health
Accident 361130677

Investigation Summary

Investigation Nr: 170084073
Event: 06/07/1994
Employee killed in 50 ft fall while servicing rig

Employee #1 was stacking tubing and a coworker, a derrick operator, was pulling tubing from an injection well. The tubing hung up on a blow out preventor ram, which was either entirely or partially closed. Before the coworker could shut the system down, the draw works pulled the top section of the telescoping mast down and Employee #1 was pulled 50 ft down with it. He died.

Keywords: JAMMED, DRAWWORKS, OIL RIG MAST, FALL, OIL WELL SERVICING

Investigated Inspection
# Inspection Age Sex Degree of Injury Nature of Injury Occupation
1 123551319 Fatality Fracture Occupation not reported
Back to Top

Thank You for Visiting Our Website

You are exiting the Department of Labor's Web server.

The Department of Labor does not endorse, takes no responsibility for, and exercises no control over the linked organization or its views, or contents, nor does it vouch for the accuracy or accessibility of the information contained on the destination server. The Department of Labor also cannot authorize the use of copyrighted materials contained in linked Web sites. Users must request such authorization from the sponsor of the linked Web site. Thank you for visiting our site. Please click the button below to continue.