Powered by GoogleTranslate

Inspection Detail

Inspection: 123429722 - H.B. Zachry Company

Inspection Information - Office: Austin Area Office

 

Inspection Nr: 123429722
Report ID: 0625400
Date Opened: 07/15/1993

Site Address:
H.B. Zachry Company
7600 S. Panam Expressway
San Antonio, TX 78285

Mailing Address:
P.O. Box 21130, San Antonio, TX 78221

Union Status: NonUnion

SIC:3272

NAICS: 0 


Inspection Type: Accident

Scope: Partial

Advanced Notice: N

Ownership: Private

Safety/Health: Safety

Close Conference: 08/11/1993

Emphasis:

Case Closed: 09/20/1993


Related Activity
Type Activity Nr Safety Health
Accident 360906044
Violation Summary
Violations/Penalties Serious Willful Repeat Other Unclass Total
Initial Violations 3 3
Current Violations 2 2
Initial Penalty $12,500 $0 $0 $0 $0 $12,500
Current Penalty $5,000 $0 $0 $0 $0 $5,000
FTA Penalty $0 $0 $0 $0 $0 $0

Violation Items
# Citation ID Citaton Type Standard Cited Issuance Date Abatement Due Date Current Penalty Initial Penalty FTA Penalty Contest Latest Event Note
1. 01001A Serious 19100242 A 08/27/1993 09/01/1993 $2,500 $5,000 $0 I - Informal Settlement  
2. 01001B Serious 19100304 F04 08/27/1993 09/01/1993 $0 $0 $0 -  
3. 01002A Serious 19100303 B01 08/27/1993 09/09/1993 $2,500 $5,000 $0 I - Informal Settlement  
4. 01002B Serious 19100305 G01 II 08/27/1993 09/09/1993 $0 $0 $0 -  
5. 01003 Serious 19100305 G02 I 08/27/1993 09/09/1993 $2,500 $2,500 $0 I - Informal Settlement Citation has been deleted.

Investigation Summary

Investigation Nr: 774372
Event: 07/14/1993
ELECTRIC SHOCK - GROUND FAULT IN IMPACT WRENCH

An employee was operating a 0.75-inch square drive impact wrench. Standing in water on the floor, the employee was removing form bolts. The impact wrench, which was not double insulated, was missing the grounding blade on the plug of its power supply cord; and the power supply cord was frayed. The employee was electrocuted by an apparent ground fault in the tool. (He had performed this job for 3 months. He had attended his employer's new employee orientation and had been given the Spanish version of the company safety manual. However, he had attended only one safety meeting in his 3 months on the job. His supervisor had given him no safety instructions before he started working.)

Keywords: E GI V, ELECTRICAL, ELECTROCUTED, ATTACHMENT PLUG, GROUND FAULT, EQUIPMENT GROUNDING, ELECTRIC CORD, ELEC PORT TOOL--MISC, WATER

Investigated Inspection
# Inspection Age Sex Degree of Injury Nature of Injury Occupation
1 123429722 Fatality Electric Shock Occupation not reported
Back to Top

Thank You for Visiting Our Website

You are exiting the Department of Labor's Web server.

The Department of Labor does not endorse, takes no responsibility for, and exercises no control over the linked organization or its views, or contents, nor does it vouch for the accuracy or accessibility of the information contained on the destination server. The Department of Labor also cannot authorize the use of copyrighted materials contained in linked Web sites. Users must request such authorization from the sponsor of the linked Web site. Thank you for visiting our site. Please click the button below to continue.

Close