Inspection Detail
Inspection: 123425522 - Myles Horak
Inspection Information - Office: Austin Area Office
Site Address: 
			   Myles Horak
			   7603 Manchaca Road
Austin, TX 78745
Mailing Address: 
			   1117 Peggotty, Austin, TX 78753
Union Status: NonUnion
SIC:1752
NAICS: 0
Inspection Type: Accident
Scope: Complete
Advanced Notice: N
Ownership: Private
Safety/Health: Safety
Close Conference: 12/07/1992
Planning Guide: Safety-Construction
Emphasis:
Case Closed: 03/22/1995
| Type | Activity Nr | Safety | Health | 
|---|---|---|---|
| Accident | 360905707 | 
| Violations/Penalties | Serious | Willful | Repeat | Other | Unclass | Total | 
|---|---|---|---|---|---|---|
| Initial Violations | 8 | 1 | 9 | |||
| Current Violations | 8 | 1 | 9 | |||
| Initial Penalty | $8,100 | $0 | $0 | $300 | $0 | $8,400 | 
| Current Penalty | $2,500 | $0 | $0 | $0 | $0 | $2,500 | 
| FTA Penalty | $0 | $0 | $0 | $0 | $0 | $0 | 
| # | Citation ID | Citaton Type | Standard Cited | Issuance Date | Abatement Due Date | Current Penalty | Initial Penalty | FTA Penalty | Contest | Latest Event | Note | 
|---|---|---|---|---|---|---|---|---|---|---|---|
| 1. | 01001 | Serious | 19260020 B01 | 01/12/1993 | 03/08/1993 | $200 | $750 | $0 | I - Informal Settlement | ||
| 2. | 01002 | Serious | 19260021 B02 | 01/12/1993 | 02/08/1993 | $400 | $1,050 | $0 | I - Informal Settlement | ||
| 3. | 01003 | Serious | 19260059 E01 | 01/12/1993 | 03/08/1993 | $150 | $600 | $0 | I - Informal Settlement | ||
| 4. | 01004 | Serious | 19260059 G08 | 01/12/1993 | 02/08/1993 | $150 | $600 | $0 | I - Informal Settlement | ||
| 5. | 01005 | Serious | 19260059 H | 01/12/1993 | 03/08/1993 | $150 | $600 | $0 | I - Informal Settlement | ||
| 6. | 01006A | Serious | 19260150 A01 | 01/12/1993 | 02/08/1993 | $450 | $1,500 | $0 | I - Informal Settlement | ||
| 7. | 01006B | Serious | 19260150 C01 I | 01/12/1993 | 01/15/1993 | $0 | $0 | $0 | - | ||
| 8. | 01007 | Serious | 19260151 A03 | 01/12/1993 | 01/15/1993 | $550 | $1,500 | $0 | I - Informal Settlement | ||
| 9. | 01008 | Serious | 19260152 F03 | 01/12/1993 | 01/15/1993 | $450 | $1,500 | $0 | I - Informal Settlement | ||
| 10. | 02001 | Other | 19030002 A01 | 01/12/1993 | 01/19/1993 | $0 | $300 | $0 | I - Informal Settlement | 
Investigation Summary
At approximately 7:00 p.m. on December 3, 1992, Employee #1 and three coworkers were installing carpeting in a private residence. Employee #1 and one coworker were spreading contact adhesive containing toluene and trichloroethane on a stairway. The weather was cold and the heater was on. There was no ventilation in the room. Vapors from the contact adhesive ignited and the resulting fire trapped Employee #1 and a coworker in an adjacent room, from which they were prevented from escaping by steel burglar bars on the window. The coworker ran back through the flames, escaping with minor burns. Employee #1 died of smoke inhalation and second- and third-degree burns to his face, back, and arms. The other two coworker escaped unharmed.
Keywords: BURN, OBSTRUCTED EGRESS, TRICHLOROETHANE, VENTILATION, FLAMMABLE VAPORS, WORK RULES, FIRE, CONSTRUCTION, TOLUENE, SMOKE INHALATION
| # | Inspection | Age | Sex | Degree of Injury | Nature of Injury | Occupation | 
|---|---|---|---|---|---|---|
| 1 | 123425522 | Fatality | Burn/Scald(Heat) | Occupation not reported | 
 Translate
Translate