Inspection Detail
Inspection: 123421752 - Torch Operating Co.
Inspection Information - Office: Austin Area Office
Site Address:
Torch Operating Co.
Friemel #1-H Lease
La Grange, TX 78945
Mailing Address:
1221 Lamar St., Suite 1600, Houston, TX 77010
Union Status: NonUnion
SIC:1311
NAICS: 0
Inspection Type: Unprog Rel
Scope: Partial
Advanced Notice: N
Ownership: Private
Safety/Health: Safety
Close Conference: 05/11/1993
Emphasis:
Case Closed: 02/02/1994
| Type | Activity Nr | Safety | Health |
|---|---|---|---|
| Accident | 360905996 |
| Violations/Penalties | Serious | Willful | Repeat | Other | Unclass | Total |
|---|---|---|---|---|---|---|
| Initial Violations | 3 | 3 | ||||
| Current Violations | ||||||
| Initial Penalty | $7,200 | $0 | $0 | $0 | $0 | $7,200 |
| Current Penalty | $0 | $0 | $0 | $0 | $0 | $0 |
| FTA Penalty | $0 | $0 | $0 | $0 | $0 | $0 |
| # | Citation ID | Citaton Type | Standard Cited | Issuance Date | Abatement Due Date | Current Penalty | Initial Penalty | FTA Penalty | Contest | Latest Event | Note |
|---|---|---|---|---|---|---|---|---|---|---|---|
| 1. | 01001A | Serious | 19100303 G02 I | 07/14/1993 | 07/19/1993 | $4,500 | $4,500 | $0 | 08/05/1993 | F - Formal Settlement | Citation has been deleted. |
| 2. | 01001B | Serious | 19100304 C02 | 07/14/1993 | 07/19/1993 | $0 | $0 | $0 | 08/05/1993 | F - Formal Settlement | Citation has been deleted. |
| 3. | 01002 | Serious | 19101200 G01 | 07/14/1993 | 08/02/1993 | $1,350 | $1,350 | $0 | 08/05/1993 | F - Formal Settlement | Citation has been deleted. |
| 4. | 01003 | Serious | 19101200 H01 III | 07/14/1993 | 08/02/1993 | $1,350 | $1,350 | $0 | 08/05/1993 | F - Formal Settlement | Citation has been deleted. |
Investigation Summary
A 24-year-old temporary laborer was working as a roustabout at an oil well drilling site. He was using a wooden handled rake to clean hardened concrete from the ground next to the rig structure. A 480-volt, dc power cable supplying electric power for lighting on the rig ran across the ground nearby. The ground was wet and muddy, and the cable had a break in its insulation. The employee was electrocuted when the rake contacted the cable.
Keywords: ELECTRICAL, HAND TOOL, E GI V, ELECTRIC CABLE, ELECTROCUTED, WATER
| # | Inspection | Age | Sex | Degree of Injury | Nature of Injury | Occupation |
|---|---|---|---|---|---|---|
| 1 | 123421752 | Occupation Not Listed |