Powered by GoogleTranslate

Inspection Detail

Case Status: CLOSED

Inspection: 1234105.015 - Us Air Filtration Inc

Inspection Information - Office: San Bernardino District Office

 

Inspection Nr: 1234105.015
Report ID: 0950633
Date Opened: 05/19/2017

Site Address:
Us Air Filtration Inc
42065 Zevo Drive, Unit 'B12'
Temecula, CA 92590

Mailing Address:
23811 Washington Ave, Unit C110-176, Murrieta, CA 92562

Union Status: NonUnion

SIC:

NAICS: 333413 


Inspection Type: Accident

Scope: Partial

Advanced Notice: N

Ownership: Private

Safety/Health: Safety

Close Conference: 08/23/2017

Emphasis:

Case Closed: 09/03/2019


Related Activity
Type Activity Nr Safety Health
Accident 1210447
Case Status: CLOSED
Violation Summary
Violations/Penalties Serious Willful Repeat Other Unclass Total
Initial Violations 2 2
Current Violations 1 1 2
Initial Penalty $25,200 $0 $0 $0 $0 $25,200
Current Penalty $12,600 $0 $0 $0 $0 $12,600
FTA Penalty $0 $0 $0 $0 $0 $0

Violation Items
# Citation ID Citation Type Standard Cited Issuance Date Abatement Due Date Current Penalty Initial Penalty FTA Penalty Contest Latest Event Note
1. 01001 Other 3203(A)(7)(C) 08/24/2017 $0 $12,600 $0 I - Informal Settlement  
2. 02001 Serious 3212(E) 08/24/2017 $12,600 $12,600 $0 I - Informal Settlement  

Investigation Summary

Investigation Nr: 95730.015
Event: 05/04/2017
Employee falls through skylight and sustains multiple injuri

At 3:30 p.m. on May 4, 2017, Employee #1, an intermittent, part-time employee, was working with a coworker on a rooftop, in close proximity to skylights and solar panels, disconnecting solar panel wiring. The employee and a coworker were dismantling the existing solar panels that covered the rooftop area above the warehouse space, using basic hand tools to disconnect the solar panel wiring. Employee #1 felt ill and stepped away from the solar panel that she was working on, and backed up against the outer rim of a skylight. Thinking the fixed object would support her, she attempted to sit down, at which time the plastic dome section of the skylight broke. The employee fell through the opening 24 feet and landed on the concrete surface below. Neither of the employees was utilizing any type of PPE. Employee #1 sustained multiple spinal injuries, bone contusions, and two hairline fractures on her sacrum. The employee also sustained muscle and ligament damage proximal to her right elbow and a fracture of the heel on her right foot. Employee #1 was transported to a local hospital where she remained for 7 days.

Keywords: Fall, Roof, Skylight

Investigated Inspection
# Inspection Age Sex Degree of Injury Nature of Injury Occupation
1 1234105.015 20 F Hospitalized injury Administrative support occupations, n.e.c.
Back to Top

Thank You for Visiting Our Website

You are exiting the Department of Labor's Web server.

The Department of Labor does not endorse, takes no responsibility for, and exercises no control over the linked organization or its views, or contents, nor does it vouch for the accuracy or accessibility of the information contained on the destination server. The Department of Labor also cannot authorize the use of copyrighted materials contained in linked Web sites. Users must request such authorization from the sponsor of the linked Web site. Thank you for visiting our site. Please click the button below to continue.