Powered by GoogleTranslate

Inspection Detail

Inspection: 123383234 - Overhead Doors Of N. E. Arkansas

Inspection Information - Office: Little Rock Area Office

 

Inspection Nr: 123383234
Report ID: 0627100
Date Opened: 06/08/1995

Site Address:
Overhead Doors Of N. E. Arkansas
2215 Grant Ave.
Jonesboro, AR 72403

Mailing Address:
P.O. Box 351, Jonesboro, AR 72403

Union Status: NonUnion

SIC:1751

NAICS: 0 


Inspection Type: Accident

Scope: Partial

Advanced Notice: N

Ownership: Private

Safety/Health: Safety

Close Conference: 11/20/1995

Planning Guide: Safety-Construction

Emphasis:

Case Closed: 12/04/1995


Related Activity
Type Activity Nr Safety Health
Accident 360935464
Violation Summary
Violations/Penalties Serious Willful Repeat Other Unclass Total
Initial Violations 1 1 2
Current Violations 1 1 2
Initial Penalty $1,500 $0 $0 $0 $0 $1,500
Current Penalty $750 $0 $0 $0 $0 $750
FTA Penalty $0 $0 $0 $0 $0 $0

Violation Items
# Citation ID Citaton Type Standard Cited Issuance Date Abatement Due Date Current Penalty Initial Penalty FTA Penalty Contest Latest Event Note
1. 01001 Serious 19260404 B01 I 11/21/1995 11/27/1995 $750 $1,500 $0 I - Informal Settlement  
2. 02001 Other 19260404 F06 11/21/1995 11/27/1995 $0 $0 $0 I - Informal Settlement  

Investigation Summary

Investigation Nr: 569954
Event: 06/07/1995
ELECTRIC SHOCK - GROUND FAULT IN ELECTRIC SCREW GUN

Two brothers were working from a platform, installing an overhead door. The platform was supported by the forks of a Turbo lift fork truck. One of the employees was using a 30-meter-long, 120-volt extension cord set attached to a Milwaukee double-insulated screw gun. The pin for the equipment grounding conductor was missing from the plug on the cord set. As he was lifting the door's spring and shaft assembly into place, one of the employees was electrocuted when he contacted a grounded portion of the building. (The cause of the electrocution was not reported.) His brother was taken to a hospital, where he was checked out and released the same day.

Keywords: E GI V, ELECTRIC SCREW GUN, ELECTRICAL, ELECTROCUTED, ATTACHMENT PLUG, GROUND FAULT, ELECTRIC CORD

Investigated Inspection
# Inspection Age Sex Degree of Injury Nature of Injury Occupation
1 123383234 Fatality Electric Shock Occupation not reported
Back to Top

Thank You for Visiting Our Website

You are exiting the Department of Labor's Web server.

The Department of Labor does not endorse, takes no responsibility for, and exercises no control over the linked organization or its views, or contents, nor does it vouch for the accuracy or accessibility of the information contained on the destination server. The Department of Labor also cannot authorize the use of copyrighted materials contained in linked Web sites. Users must request such authorization from the sponsor of the linked Web site. Thank you for visiting our site. Please click the button below to continue.