Powered by GoogleTranslate

Inspection Detail

Case Status: CLOSED

Inspection: 1233723.015 - Vcna Prestige Gunite, Inc.

Inspection Information - Office: Fort Lauderdale Area Office

 

Inspection Nr: 1233723.015
Report ID: 0418800
Date Opened: 05/18/2017

Site Address:
Vcna Prestige Gunite, Inc.
3825 Selvitz Road
Fort Pierce, FL 34981

Mailing Address:
3825 Selvitz Road, Fort Pierce, FL 34981

Union Status: NonUnion

SIC:

NAICS: 238140/Masonry Contractors


Inspection Type: Fat/Cat

Scope: Partial

Advanced Notice: N

Ownership: Private

Safety/Health: Safety

Close Conference: 05/18/2017

Emphasis:

Case Closed: 12/22/2017


Related Activity
Type Activity Nr Safety Health
Referral 1215629 Yes
Accident 1234847
Accident 1281977
Case Status: CLOSED

Investigation Summary

Investigation Nr: 100510.015
Event: 05/23/2017
Employee is killed by lightning strike

At 7:00 p.m. on May 23, 2017, an employee was spreading gunite. A lightning strike hit a piece of wood and also hit the employee. The employee was found unconscious. He was transported to the hospital, and was put on life support. He was later taken off life support and died.

Keywords: Lightning

Investigated Inspection
# Inspection Age Sex Degree of Injury Nature of Injury Occupation
1 1233723.015 46 M Fatality Construction laborers
Back to Top

Thank You for Visiting Our Website

You are exiting the Department of Labor's Web server.

The Department of Labor does not endorse, takes no responsibility for, and exercises no control over the linked organization or its views, or contents, nor does it vouch for the accuracy or accessibility of the information contained on the destination server. The Department of Labor also cannot authorize the use of copyrighted materials contained in linked Web sites. Users must request such authorization from the sponsor of the linked Web site. Thank you for visiting our site. Please click the button below to continue.