Powered by GoogleTranslate

Inspection Detail

Inspection: 123304909 - B & E Pipe And Basin Cleaners, Inc.

Inspection Information - Office: Bridgeport Area Office

 

Inspection Nr: 123304909
Report ID: 0111500
Date Opened: 03/03/2000

Site Address:
B & E Pipe And Basin Cleaners, Inc.
22 Burton Dr.
Cheshire, CT 06410

Mailing Address:
97 Hawthorne Dr., Southington, CT 06489

Union Status: Union

SIC:4959

NAICS: 0 


Inspection Type: Referral

Scope: Partial

Advanced Notice: N

Ownership: Private

Safety/Health: Safety

Close Conference: 04/13/2000

Emphasis:

Case Closed: 05/10/2000


Related Activity
Type Activity Nr Safety Health
Referral 201523172 Yes
Violation Summary
Violations/Penalties Serious Willful Repeat Other Unclass Total
Initial Violations 6 6
Current Violations 6 6
Initial Penalty $5,100 $0 $0 $0 $0 $5,100
Current Penalty $5,100 $0 $0 $0 $0 $5,100
FTA Penalty $0 $0 $0 $0 $0 $0

Violation Items
# Citation ID Citaton Type Standard Cited Issuance Date Abatement Due Date Current Penalty Initial Penalty FTA Penalty Contest Latest Event Note
1. 01001A Serious 19100134 C01 04/13/2000 05/16/2000 $1,050 $1,050 $0 -  
2. 01001B Serious 19100134 D01 I 04/13/2000 05/16/2000 $0 $0 $0 -  
3. 01001C Serious 19100134 E01 04/13/2000 05/16/2000 $0 $0 $0 -  
4. 01002A Serious 19100146 C01 04/13/2000 05/16/2000 $1,050 $1,050 $0 -  
5. 01002B Serious 19100146 C04 04/13/2000 05/16/2000 $0 $0 $0 -  
6. 01003A Serious 19100146 C05 IIC 04/13/2000 04/18/2000 $1,050 $1,050 $0 -  
7. 01003B Serious 19100146 D03 VI 04/13/2000 04/18/2000 $0 $0 $0 -  
8. 01004 Serious 19100146 D03 III 04/13/2000 04/18/2000 $1,050 $1,050 $0 -  
9. 01005A Serious 19100146 G01 04/13/2000 05/16/2000 $450 $450 $0 -  
10. 01005B Serious 19100146 H01 04/13/2000 05/16/2000 $0 $0 $0 -  
11. 01006A Serious 19101200 E01 04/13/2000 05/16/2000 $450 $450 $0 -  
12. 01006B Serious 19101200 H02 III 04/13/2000 05/16/2000 $0 $0 $0 -  

Investigation Summary

Investigation Nr: 201520715
Event: 03/01/2000
EmployeeSuffers Burns In Flash Fire

Employee #1 was applying "Plasti-Dip", a synthetic rubber coating, with a paintbrush and roller to the inside of a truck-mounted water tank. The tank was approximately 5-ft by 5-ft by 5-ft and Employee #1 was standing inside the tank of the truck which was parked inside the storage building. Employee #1 was using a small wooden ladder as means of entering and exiting the tank. The tank was completely open on top. The vapors ignited from an undetermined ignition source, possibly static electricity, and a flash fire erupted in the tank. Employee #1 jumped from the tank as other employees extinguished the fire with a 120-BC-rated fire extinguisher. Employee #1 was hospitalized.

Keywords: BURN, HEAT, STATIC ELECTRICITY, VAPOR, FIRE, LADDER, COMBUSTIBLE LIQUID, TANK

Investigated Inspection
# Inspection Age Sex Degree of Injury Nature of Injury Occupation
1 123304909 Hospitalized injury Burn/Scald(Heat) Laborers, except construction
Back to Top

Thank You for Visiting Our Website

You are exiting the Department of Labor's Web server.

The Department of Labor does not endorse, takes no responsibility for, and exercises no control over the linked organization or its views, or contents, nor does it vouch for the accuracy or accessibility of the information contained on the destination server. The Department of Labor also cannot authorize the use of copyrighted materials contained in linked Web sites. Users must request such authorization from the sponsor of the linked Web site. Thank you for visiting our site. Please click the button below to continue.