Inspection Detail
Inspection: 123273161 - R.B. Hash & Associates
Inspection Information - Office: Houston South Area Office
Site Address:
R.B. Hash & Associates
1419 Nantucket
Houston, TX 77057
Mailing Address:
1281 Britmore, Houston, TX 77043
Union Status: NonUnion
SIC:1761
NAICS: 0
Inspection Type: Accident
Scope: Partial
Advanced Notice: N
Ownership: Private
Safety/Health: Safety
Close Conference: 11/17/2000
Planning Guide: Safety-Construction
Emphasis:
Case Closed: 01/31/2002
| Type | Activity Nr | Safety | Health |
|---|---|---|---|
| Accident | 360975213 |
| Violations/Penalties | Serious | Willful | Repeat | Other | Unclass | Total |
|---|---|---|---|---|---|---|
| Initial Violations | 1 | 1 | ||||
| Current Violations | ||||||
| Initial Penalty | $1,500 | $0 | $0 | $0 | $0 | $1,500 |
| Current Penalty | $0 | $0 | $0 | $0 | $0 | $0 |
| FTA Penalty | $0 | $0 | $0 | $0 | $0 | $0 |
| # | Citation ID | Citaton Type | Standard Cited | Issuance Date | Abatement Due Date | Current Penalty | Initial Penalty | FTA Penalty | Contest | Latest Event | Note |
|---|---|---|---|---|---|---|---|---|---|---|---|
| 1. | 01001 | Serious | 19260404 C01 IV | 05/15/2001 | 05/18/2001 | $0 | $1,500 | $0 | 06/13/2001 | J - ALJ Decision | Citation has been deleted. |
Investigation Summary
Three employees were installing a tile roof on a three-story residence. A 19.9-kilovolt (phase to ground) overhead power line ran 1.8 meters above and 0.9 to 1.2 meters horizontally from the eve. One of the employees was positioning a 3-meter length of flashing and contacted the power line. He was electrocuted. (He also fell to grade level.)
Keywords: OVERHEAD POWER LINE, ROOF, ELECTRICAL, ELECTROCUTED, E C, ROOFER, METAL STRIP
| # | Inspection | Age | Sex | Degree of Injury | Nature of Injury | Occupation |
|---|---|---|---|---|---|---|
| 1 | 123273161 | Fatality | Electric Shock | Roofers |
Translate