Inspection Detail
Inspection: 123267957 - Mcbride Electric Inc.
Inspection Information - Office: Houston South Area Office
Site Address:
Mcbride Electric Inc.
1229 34th St.
Houston, TX 77018
Mailing Address:
P. O. Box 924208, Houston, TX 77292
Union Status: NonUnion
SIC:1731
NAICS: 0
Inspection Type: Accident
Scope: Partial
Advanced Notice: Y
Ownership: Private
Safety/Health: Safety
Close Conference: 07/20/1999
Emphasis:
Case Closed: 12/14/1999
| Type | Activity Nr | Safety | Health |
|---|---|---|---|
| Accident | 360975122 |
Investigation Summary
Two employees from an electrical contractor were working at a residence, replacing a front porch light, installing a ground-fault circuit interrupter in a guest bathroom, and installing a lighting fixture in the shower area of the guest bathroom. One of the employees was installing the front porch light, and the other was working in the attic. The 120-volt, 15-ampere circuits for the areas where work was being performed were deenergized. The employees used meters to test the wiring. The employee working on the porch light went to the attic. He was electrocuted when he contacted an air conditioning duct that had been energized by a ground fault.
Keywords: ATTIC, DUCT, ELECTRICAL, E GI VII, ELECTROCUTED, GROUND FAULT, EQUIPMENT GROUNDING
| # | Inspection | Age | Sex | Degree of Injury | Nature of Injury | Occupation |
|---|---|---|---|---|---|---|
| 1 | 123267957 | Fatality | Electric Shock | Electricians |