Inspection Detail
Inspection: 123257230 - Environmental Preservation Associates, Inc.
Inspection Information - Office: Allentown Area Office
Site Address:
Environmental Preservation Associates, Inc.
1337 And 1339 Allen Street, Gross Tower
Allentown, PA 18102
Mailing Address:
5290 West Coplay Road, Whitehall, PA 18052
Union Status: NonUnion
SIC:1629
NAICS: 0
Inspection Type: Referral
Scope: Complete
Advanced Notice: N
Ownership: Private
Safety/Health: Safety
Close Conference: 09/20/1994
Emphasis:
Case Closed: 03/28/2003
| Type | Activity Nr | Safety | Health |
|---|---|---|---|
| Referral | 902663780 | Yes |
| Violations/Penalties | Serious | Willful | Repeat | Other | Unclass | Total |
|---|---|---|---|---|---|---|
| Initial Violations | 5 | 1 | 6 | |||
| Current Violations | 5 | 1 | 6 | |||
| Initial Penalty | $12,300 | $42,000 | $0 | $0 | $0 | $54,300 |
| Current Penalty | $7,380 | $25,200 | $0 | $0 | $0 | $32,580 |
| FTA Penalty | $0 | $0 | $0 | $0 | $0 | $0 |
| # | Citation ID | Citaton Type | Standard Cited | Issuance Date | Abatement Due Date | Current Penalty | Initial Penalty | FTA Penalty | Contest | Latest Event | Note |
|---|---|---|---|---|---|---|---|---|---|---|---|
| 1. | 01001 | Serious | 5A0001 | 09/30/1994 | 10/07/1994 | $900 | $1,500 | $0 | I - Informal Settlement | ||
| 2. | 01002 | Serious | 19260020 B02 | 09/30/1994 | 10/07/1994 | $900 | $1,500 | $0 | I - Informal Settlement | ||
| 3. | 01003 | Serious | 19260651 B04 | 09/30/1994 | 10/07/1994 | $3,780 | $6,300 | $0 | I - Informal Settlement | ||
| 4. | 01004 | Serious | 19260651 C02 | 09/30/1994 | 10/07/1994 | $900 | $1,500 | $0 | I - Informal Settlement | ||
| 5. | 01005A | Serious | 19260651 J02 | 09/30/1994 | 10/07/1994 | $900 | $1,500 | $0 | I - Informal Settlement | ||
| 6. | 01005B | Serious | 19260651 K02 | 09/30/1994 | 10/07/1994 | $0 | $0 | $0 | I - Informal Settlement | ||
| 7. | 02001 | Willful | 19260652 A01 | 09/30/1994 | 10/07/1994 | $25,200 | $42,000 | $0 | I - Informal Settlement |
Investigation Summary
At approximately 7:00 p.m. on June 9, 1994, employees were using a John Deere excavator to bust concrete into an excavation hole at a high-rise facility for the elderly. The hole had been dug on May 23 to remove an underground storage tank. In the process, a natural gas pipeline had been exposed, and the employer failed to support or adequately protect the line. The concrete blasting continued uninterrupted for between 5 and 6 hours a day, and the vibrations caused the unsecured pipeline to separate from its compression coupling. Natural gas permeated the ground and entered the building; the gas exploded and caught fire. Damage to the exterior pipe covering indicated that there had also been physical damage to the pipe. No employee injuries were reported as a result of this accident.
Keywords: FLAMMABLE VAPORS, UNSECURED, WORK RULES, FIRE, CONSTRUCTION, NATURAL GAS, VIBRATIONS, EXPLOSION, PIPELINE, GAS LEAK
| # | Inspection | Age | Sex | Degree of Injury | Nature of Injury | Occupation |
|---|---|---|---|---|---|---|
| 1 | 123257230 | Occupation Not Listed |