Investigation Summary
At approximately 8:00 p.m. on April 27, 2017, an employee, an owner, was preparing to drain refrigerant from the system. The owner loosened the valve. The Schrader valve was missing its core, so R-22 refrigerant flashed off and burned the owner's hands. The owner received serious burns from the refrigerant and was hospitalized.
Keywords: Burn, Chemical, Chemical Burn, Hand
| # | Inspection | Age | Sex | Degree of Injury | Nature of Injury | Occupation |
|---|---|---|---|---|---|---|
| 1 | 1232037.015 | 60 | M | Hospitalized injury |