Inspection: 1230865.015 - Wwf Operating Company
Inspection Information - Office: Dallas Area Office
Site Address:
Wwf Operating Company
3333 Dan Morton Dr
Dallas, TX 75236
Mailing Address:
3333 Dan Morton Dr, Dallas, TX 75236
Union Status: NonUnion
SIC:
NAICS: 311511/Fluid Milk Manufacturing
Inspection Type: Referral
Scope: Partial
Advanced Notice: N
Ownership: Private
Safety/Health: Health
Close Conference: 05/08/2017
Emphasis:
Case Closed: 08/25/2017
| Type | Activity Nr | Safety | Health |
|---|---|---|---|
| Referral | 1207940 | Yes | Yes |
| Violations/Penalties | Serious | Willful | Repeat | Other | Unclass | Total |
|---|---|---|---|---|---|---|
| Initial Violations | 1 | 1 | ||||
| Current Violations | ||||||
| Initial Penalty | $12,675 | $0 | $0 | $0 | $0 | $12,675 |
| Current Penalty | $0 | $0 | $0 | $0 | $0 | $0 |
| FTA Penalty | $0 | $0 | $0 | $0 | $0 | $0 |
| # | Citation ID | Citaton Type | Standard Cited | Issuance Date | Abatement Due Date | Current Penalty | Initial Penalty | FTA Penalty | Contest | Latest Event | Note |
|---|---|---|---|---|---|---|---|---|---|---|---|
| 1. | 01001 | Serious | 19101200 H03 III | 08/02/2017 | 08/28/2017 | $0 | $12,675 | $0 | I - Informal Settlement | Citation has been deleted. |
Investigation Summary
At 11:30 a.m. on May 2, 2017, a sanitation employee was removing a water hose from the supply side of the AC-101 chemical pump. The employee was splashed with corrosive chemicals and sustained second degree burns to his private areas. The employee was hospitalized and treated for his injuries
Keywords: Burn, Chemical, Chemical Burn, Corrosion
| # | Inspection | Age | Sex | Degree of Injury | Nature of Injury | Occupation |
|---|---|---|---|---|---|---|
| 1 | 1230865.015 | 55 | M | Hospitalized injury |