Inspection Detail
Inspection: 1228636.015 - Chemaid Laboratories Inc
Inspection Information - Office: Hasbrouck Heights Area Office
Site Address:
Chemaid Laboratories Inc
100 Mayhill Street
Saddle Brook, NJ 07663
Mailing Address:
100 Mayhill Street, Saddle Brook, NJ 07663
Union Status: NonUnion
SIC:
NAICS: 325620/Toilet Preparation Manufacturing
Inspection Type: Referral
Scope: Partial
Advanced Notice: N
Ownership: LocalGovt
Safety/Health: Safety
Close Conference: 04/27/2017
Emphasis: N:Amputate
Case Closed: 07/05/2017
Type | Activity Nr | Safety | Health |
---|---|---|---|
Referral | 1206565 | Yes |
Investigation Summary
At approximately 8:00 p.m. on April 26, 2017, an employee was speaking with a coworker and leaned against a machine for support. The employee's hand was caught on a conveyor belt and her left finger was caught in a pinch point causing an amputation of the fingertip. The employee was hospitalized and treated for her injuries.
Keywords: Amputated, Conveyor Belt, Finger, Machine Guarding
# | Inspection | Age | Sex | Degree of Injury | Nature of Injury | Occupation |
---|---|---|---|---|---|---|
1 | 1228636.015 | 50 | F | Hospitalized injury | Assemblers |