Inspection Detail
Inspection: 1227556.015 - Techmetals, Inc.
Inspection Information - Office: Cincinnati Area Office
Site Address:
Techmetals, Inc.
345 Springfield Street
Dayton, OH 45403
Mailing Address:
345 Springfield Street, Dayton, OH 45403
Union Status: NonUnion
SIC:
NAICS: 332813/ Electroplating, Plating, Polishing, Anodizing, and Coloring
Inspection Type: Referral
Scope: Partial
Advanced Notice: N
Ownership: Private
Safety/Health: Health
Close Conference: 04/26/2017
Emphasis:
Case Closed: 07/11/2017
Type | Activity Nr | Safety | Health |
---|---|---|---|
Referral | 1204041 | Yes |
Violations/Penalties | Serious | Willful | Repeat | Other | Unclass | Total |
---|---|---|---|---|---|---|
Initial Violations | 1 | 1 | ||||
Current Violations | ||||||
Initial Penalty | $8,311 | $0 | $0 | $0 | $0 | $8,311 |
Current Penalty | $0 | $0 | $0 | $0 | $0 | $0 |
FTA Penalty | $0 | $0 | $0 | $0 | $0 | $0 |
# | Citation ID | Citaton Type | Standard Cited | Issuance Date | Abatement Due Date | Current Penalty | Initial Penalty | FTA Penalty | Contest | Latest Event | Note |
---|---|---|---|---|---|---|---|---|---|---|---|
1. | 01001 | Serious | 19100132 D01 I | 06/19/2017 | 07/14/2017 | $0 | $8,311 | $0 | I - Informal Settlement | Citation has been deleted. |
Investigation Summary
At 6:15 a.m. on April 20, 2017, an employee was transferring hot water wash from one tank to another, when he was splashed with the water. The water measured between 140 degrees and 150 degrees Fahrenheit and he was burned. The employee was hospitalized and received treatment for his injuries.
Keywords: Burn, Hot Water, Hot Water Tank, Spill
# | Inspection | Age | Sex | Degree of Injury | Nature of Injury | Occupation |
---|---|---|---|---|---|---|
1 | 1227556.015 | 35 | M | Hospitalized injury | Technicians, n.e.c. |