Inspection Detail
Inspection: 122495849 - Continental Plastic Container
Inspection Information - Office: Chicago North Area Office
Site Address:
Continental Plastic Container
2727 East Higgins
Elk Grove Village, IL 60007
Mailing Address:
, , 00000
Union Status: Union
SIC:3221
NAICS: 0
Inspection Type: Accident
Scope: Partial
Advanced Notice: N
Ownership: Private
Safety/Health: Health
Close Conference: 04/14/1997
Planning Guide: Health-Manufacturing
Emphasis:
Case Closed: 01/22/1999
| Type | Activity Nr | Safety | Health |
|---|---|---|---|
| Accident | 101260099 | ||
| Referral | 201260197 | Yes |
| Violations/Penalties | Serious | Willful | Repeat | Other | Unclass | Total |
|---|---|---|---|---|---|---|
| Initial Violations | 5 | 5 | ||||
| Current Violations | 4 | 4 | ||||
| Initial Penalty | $12,500 | $0 | $0 | $0 | $0 | $12,500 |
| Current Penalty | $7,500 | $0 | $0 | $0 | $0 | $7,500 |
| FTA Penalty | $0 | $0 | $0 | $0 | $0 | $0 |
| # | Citation ID | Citaton Type | Standard Cited | Issuance Date | Abatement Due Date | Current Penalty | Initial Penalty | FTA Penalty | Contest | Latest Event | Note |
|---|---|---|---|---|---|---|---|---|---|---|---|
| 1. | 01001 | Serious | 19100106 E06 I | 04/16/1997 | 04/21/1997 | $2,500 | $2,500 | $0 | I - Informal Settlement | Citation has been deleted. | |
| 2. | 01002 | Serious | 19100307 B02 | 04/16/1997 | 04/21/1997 | $2,500 | $2,500 | $0 | I - Informal Settlement | ||
| 3. | 01003 | Serious | 19100307 B03 | 04/16/1997 | 04/21/1997 | $2,500 | $2,500 | $0 | I - Informal Settlement | ||
| 4. | 01004 | Serious | 19101200 B04 III | 04/16/1997 | 04/21/1997 | $2,500 | $2,500 | $0 | I - Informal Settlement | ||
| 5. | 01005 | Serious | 19101200 H03 III | 04/16/1997 | 04/21/1997 | $0 | $2,500 | $0 | I - Informal Settlement |
Investigation Summary
An employee was working alone in the quality assurance section of a plant. A container of toluene fell to the floor from the work counter. The employee placed the container back on the counter. Apparently, as he tried to clean up the spilled toluene, it ignited, engulfing the room and the employee in flames. He died from his injuries. Investigation revealed that the ignition source was most likely static electricity.
Keywords: BURN, STATIC ELECTRICITY, E GI III, ELECTRICAL, VENTILATION, TOLUENE, EXPLOSION
| # | Inspection | Age | Sex | Degree of Injury | Nature of Injury | Occupation |
|---|---|---|---|---|---|---|
| 1 | 122495849 | Fatality | Burn(Chemical) | Occupation not reported |
Translate