Inspection Detail
Inspection: 1224935.015 - Stokes Contracting, Inc.
Inspection Information - Office: Savannah Area Office
Site Address:
Stokes Contracting, Inc.
201 Oxnard Drive
Port Wentworth, GA 31407
Mailing Address:
2534 Old River Road, Bloomingdale, GA 31302
Union Status: NonUnion
SIC:
NAICS: 561790/Other Services to Buildings and Dwellings
Inspection Type: Referral
Scope: Partial
Advanced Notice: N
Ownership: Private
Safety/Health: Safety
Close Conference: 06/15/2017
Emphasis: P:Forklift, L:Forklift
Case Closed: 07/10/2017
Type | Activity Nr | Safety | Health |
---|---|---|---|
Referral | 1200542 | Yes |
Investigation Summary
At 11:00 a.m. on April 10, 2017, Employee #1 was fueling a forklift cylinder with propane. The nozzle valve was bumped open when the nozzle reel retracted the fuel hose. When the employee noticed that the valve was open, he went to shut it off. The employee was wearing personal protective equipment, but had removed it when the fueling was complete. The gas cloud ignited upon touch, and Employee #1 sustained second degree burns to his arms, neck and face. Employee #1 was hospitalized for treatment.
Keywords: Arm, Burn, Combustible Liquid, Face, Fire, Neck, Powered Industrial Vehicle, Propane
# | Inspection | Age | Sex | Degree of Injury | Nature of Injury | Occupation |
---|---|---|---|---|---|---|
1 | 1224935.015 | 36 | M | Fatality |