Powered by GoogleTranslate

Inspection Detail

Inspection: 122484348 - Tri-County Radio Inc

Inspection Information - Office: Appleton Area Office

 

Inspection Nr: 122484348
Report ID: 0521100
Date Opened: 07/15/1994

Site Address:
Tri-County Radio Inc
5100 Block, County Hwy P
Manitowoc, WI 54220

Mailing Address:
1050 Linden Street, Cleveland, WI 53015

Union Status: NonUnion

SIC:4832

NAICS: 0 


Inspection Type: Accident

Scope: Partial

Advanced Notice: N

Ownership: Private

Safety/Health: Safety

Close Conference: 07/21/1994

Emphasis:

Case Closed: 10/11/1994


Related Activity
Type Activity Nr Safety Health
Accident 361106156
Violation Summary
Violations/Penalties Serious Willful Repeat Other Unclass Total
Initial Violations 1 1 2
Current Violations 1 1 2
Initial Penalty $4,200 $0 $0 $3,000 $0 $7,200
Current Penalty $4,200 $0 $0 $500 $0 $4,700
FTA Penalty $0 $0 $0 $0 $0 $0

Violation Items
# Citation ID Citaton Type Standard Cited Issuance Date Abatement Due Date Current Penalty Initial Penalty FTA Penalty Contest Latest Event Note
1. 01001A Serious 19100332 B01 09/07/1994 09/14/1994 $4,200 $4,200 $0 I - Informal Settlement  
2. 01001B Serious 19100333 C03 IB 09/07/1994 09/12/1994 $0 $0 $0 -  
3. 02001 Other 19040008 A 09/07/1994 09/12/1994 $500 $3,000 $0 I - Informal Settlement  

Investigation Summary

Investigation Nr: 845883
Event: 07/14/1994
ELECTRIC SHOCK - CONTACT WITH OVERHEAD LINE THRU ANTENNA

An announcer and a salesperson for a local radio station were at an appliance store, setting up for a remote broadcast for a tent sale. It was drizzling at the time. The announcer parked the radio station's van next to the tent. He then pulled a telescoping antenna out of the van and locked the antenna sections into place. He placed the bottom of the mast in a swivel device attached to the lower side of the van. Both employees lifted the antenna . When the antenna was up, the salesperson reached for an attachment bolt with one hand as the antenna contacted a 14.4-kilovolt overhead power line. The announcer was electrocuted. The salesperson received an electric shock and sustained burns on his left hand and on both his feet. He was hospitalized for his injuries.

Keywords: BURN, OVERHEAD POWER LINE, ELECTRICAL, TELECOM WORK, E TC, ELECTROCUTED, ELECTRIC SHOCK, ANTENNA

Investigated Inspection
# Inspection Age Sex Degree of Injury Nature of Injury Occupation
1 122484348 Fatality Electric Shock Announcers
2 122484348 Hospitalized injury Electric Shock Advertising and related sales occupations
Back to Top

Thank You for Visiting Our Website

You are exiting the Department of Labor's Web server.

The Department of Labor does not endorse, takes no responsibility for, and exercises no control over the linked organization or its views, or contents, nor does it vouch for the accuracy or accessibility of the information contained on the destination server. The Department of Labor also cannot authorize the use of copyrighted materials contained in linked Web sites. Users must request such authorization from the sponsor of the linked Web site. Thank you for visiting our site. Please click the button below to continue.

Close