Inspection Detail
Inspection: 122310758 - Brown Nationalease
Inspection Information - Office: Naperville Area Office
Site Address:
Brown Nationalease
Rr #1, Box 305
Princeton, IL 61356
Mailing Address:
, , 00000
Union Status: NonUnion
SIC:7538
NAICS: 0
Inspection Type: Accident
Scope: Partial
Advanced Notice: N
Ownership: Private
Safety/Health: Safety
Close Conference: 08/03/1995
Emphasis:
Case Closed: 08/11/1995
| Type | Activity Nr | Safety | Health |
|---|---|---|---|
| Accident | 360686653 |
Investigation Summary
An employee was welding the framework on a flatbed trailer on a hot and humid day. His welding rod was spent, and he was replacing it. He had a new rod in one hand and the welding electrode holder in the other. Apparently, the employee was trying to insert the rod into the holder while it was still energized, and the rod touched his metal-framed glasses. The employee was electrocuted. Burn marks were found where the metal frame touched his temple and in two places on the bridge of his nose.
Keywords: E GI IV, ELECTRICAL, ELECTROCUTED, WELDER, WELDING, WELDING ELECTRODE
| # | Inspection | Age | Sex | Degree of Injury | Nature of Injury | Occupation |
|---|---|---|---|---|---|---|
| 1 | 122310758 | Fatality | Electric Shock | Occupation not reported |