Inspection Detail
Inspection: 1222991.015 - Foley Cellulose, Llc
Inspection Information - Office: Jacksonville Area Office
Site Address:
Foley Cellulose, Llc
1 Buckeye Drive
Perry, FL 32348
Mailing Address:
1 Buckeye Drive, Perry, FL 32348
Union Status: Union
SIC:
NAICS: 322110/Pulp Mills
Inspection Type: Referral
Scope: Partial
Advanced Notice: N
Ownership: Private
Safety/Health: Safety
Close Conference: 08/24/2017
Emphasis:
Case Closed: 10/30/2017
| Type | Activity Nr | Safety | Health |
|---|---|---|---|
| Referral | 1198390 | Yes |
| Violations/Penalties | Serious | Willful | Repeat | Other | Unclass | Total |
|---|---|---|---|---|---|---|
| Initial Violations | 1 | 1 | ||||
| Current Violations | 1 | 1 | ||||
| Initial Penalty | $7,470 | $0 | $0 | $0 | $0 | $7,470 |
| Current Penalty | $4,482 | $0 | $0 | $0 | $0 | $4,482 |
| FTA Penalty | $0 | $0 | $0 | $0 | $0 | $0 |
| # | Citation ID | Citaton Type | Standard Cited | Issuance Date | Abatement Due Date | Current Penalty | Initial Penalty | FTA Penalty | Contest | Latest Event | Note |
|---|---|---|---|---|---|---|---|---|---|---|---|
| 1. | 01001 | Serious | 19100132 D01 | 08/29/2017 | 10/17/2017 | $4,482 | $7,470 | $0 | I - Informal Settlement |
Investigation Summary
At 1:10 p.m. on April 3, 2017, an employee took a pulp sample from washer W-10. He was standing on a catwalk platform between washers W-10 and W-11 closing up a sample bag and preparing to return to the lab with the sample obtained during a pulp experimental order trial process. Steam, heated pulp material and or heated water escaped from washer W-11 sample access port hood, causing second and third degree burns to the employee's right arm/hand and less severe burns to chest, back, left arm, thigh and back.
Keywords: Accidental Discharge, Flowing Material, Heat
| # | Inspection | Age | Sex | Degree of Injury | Nature of Injury | Occupation |
|---|---|---|---|---|---|---|
| 1 | 1222991.015 | 42 | F | Hospitalized injury | Chemical technicians |
Translate