Powered by GoogleTranslate

Inspection Detail

Inspection: 122220114 - Coastal Refining & Marketing, Inc.

Inspection Information - Office: Corpus Christi Area Office

 

Inspection Nr: 122220114
Report ID: 0626000
Date Opened: 12/22/1995

Site Address:
Coastal Refining & Marketing, Inc.
1300 Cantwell Lane (West Plant)
Corpus Christi, TX 78407

Mailing Address:
P.O.Box 109, Corpus Christi, TX 78403

Union Status: NonUnion

SIC:2911

NAICS: 0 


Inspection Type: Accident

Scope: Partial

Advanced Notice: N

Ownership: Private

Safety/Health: Health

Close Conference: 06/20/1996

Emphasis:

Case Closed: 07/11/1996


Related Activity
Type Activity Nr Safety Health
Accident 360922819
Violation Summary
Violations/Penalties Serious Willful Repeat Other Unclass Total
Initial Violations 5 1 6
Current Violations 5 1 6
Initial Penalty $35,000 $0 $0 $0 $70,000 $105,000
Current Penalty $35,000 $0 $0 $0 $70,000 $105,000
FTA Penalty $0 $0 $0 $0 $0 $0

Violation Items
# Citation ID Citaton Type Standard Cited Issuance Date Abatement Due Date Current Penalty Initial Penalty FTA Penalty Contest Latest Event Note
1. 01001 Serious 19100119 D03 IB 06/20/1996 07/23/1996 $7,000 $7,000 $0 -  
2. 01002 Serious 19100119 E01 06/20/1996 07/23/1996 $7,000 $7,000 $0 -  
3. 01003 Serious 19100119 E02 06/20/1996 07/08/1996 $7,000 $7,000 $0 -  
4. 01004 Serious 19100119 E03 I 06/20/1996 07/08/1996 $7,000 $7,000 $0 -  
5. 01005 Serious 19100119 F03 06/20/1996 07/03/1996 $7,000 $7,000 $0 -  
6. 02001 Unclass 19100119 F01 IB 06/20/1996 07/08/1996 $70,000 $70,000 $0 -  

Investigation Summary

Investigation Nr: 14402796
Event: 12/22/1995
Employee killed in coker fire

Employee #1, of Coastal Refining and Marketing, Inc., was working as a coker helper in the delayed coking unit, switching the drums, blowing down the west drum, and cooling the west drum. Employee #1 and his lead operator were in the unit to open the main drain line and the alternate drain line, when Employee #1 opened the wedge plug on the alternate drain line on the east drum instead of on the west drum. Hot feed oil was being pumped into the east drum when the wedge plug was opened. Hot oil drained out the drain line into the sluiceway and was ignited. A flash fire occurred and Employee #1 sustained fatal burns. The lead operator was approximately 15 feet away and did not sustain any burns.

Keywords: BURN, DRAIN PLUG, WORK RULES, FIRE, COKE DRUM, COMBUSTIBLE LIQUID, INATTENTION

Investigated Inspection
# Inspection Age Sex Degree of Injury Nature of Injury Occupation
1 122220114 Fatality Burn/Scald(Heat) Occupation not reported
Back to Top

Thank You for Visiting Our Website

You are exiting the Department of Labor's Web server.

The Department of Labor does not endorse, takes no responsibility for, and exercises no control over the linked organization or its views, or contents, nor does it vouch for the accuracy or accessibility of the information contained on the destination server. The Department of Labor also cannot authorize the use of copyrighted materials contained in linked Web sites. Users must request such authorization from the sponsor of the linked Web site. Thank you for visiting our site. Please click the button below to continue.

Close