Powered by GoogleTranslate

Inspection Detail

Inspection: 122180011 - La Favorita Inc.

Inspection Information - Office: Dallas Area Office

 

Inspection Nr: 122180011
Report ID: 0626300
Date Opened: 10/13/1998

Site Address:
La Favorita Inc.
3407 W. Davis
Dallas, TX 75211

Mailing Address:
, , 00000

Union Status: NonUnion

SIC:2099

NAICS: 0 


Inspection Type: Accident

Scope: Partial

Advanced Notice: N

Ownership: Private

Safety/Health: Safety

Close Conference: 03/30/1999

Emphasis: S:Amputations

Case Closed: 11/22/1999


Related Activity
Type Activity Nr Safety Health
Accident 360151989
Violation Summary
Violations/Penalties Serious Willful Repeat Other Unclass Total
Initial Violations 3 2 5
Current Violations 4 1 5
Initial Penalty $6,750 $56,000 $0 $0 $0 $62,750
Current Penalty $6,462 $23,038 $0 $0 $0 $29,500
FTA Penalty $0 $0 $0 $0 $0 $0

Violation Items
# Citation ID Citaton Type Standard Cited Issuance Date Abatement Due Date Current Penalty Initial Penalty FTA Penalty Contest Latest Event Note
1. 01001 Serious 19100147 C01 04/06/1999 05/21/1999 $822 $1,750 $0 04/28/1999 F - Formal Settlement  
2. 01002 Serious 19100305 J02 I 04/06/1999 07/01/1999 $1,175 $2,500 $0 04/28/1999 F - Formal Settlement  
3. 01003 Serious 19100332 B01 04/06/1999 04/30/1999 $0 $2,500 $0 04/28/1999 F - Formal Settlement  
4. 02001 Serious 19040002 A 04/06/1999 04/12/1999 $4,465 $7,000 $0 04/28/1999 F - Formal Settlement  
5. 02002 Willful 19100334 A03 II 04/06/1999 04/30/1999 $23,038 $49,000 $0 04/28/1999 F - Formal Settlement  

Investigation Summary

Investigation Nr: 200780500
Event: 10/10/1998
electric shock - ground fault in extruder

A machine operator working in the cooking area on a tortilla line plugged a portable extruder into an overhead pendant connector. The twist-lock plug on the power supply cord on the extruder had a portion of the grounding prong removed, enabling it to be inserted into the connector in incorrect orientations. The employee inserted the plug into the connector so that the equipment grounding pin was connected to the ungrounded circuit conductor, energizing the frame of the extruder. The employee was electrocuted when he contacted the tortilla oven and the extruder at the same time. Another employee received an electric shock but did not receive any medical attention. (This employee was not listed on an injury line on the original form.)

Keywords: E GI V, ELECTRICAL, ELECTROCUTED, ATTACHMENT PLUG, GROUND FAULT, EQUIPMENT GROUNDING, ELECTRIC SHOCK, ELEC EQUIPMENT--MISC

Investigated Inspection
# Inspection Age Sex Degree of Injury Nature of Injury Occupation
1 122180011 Fatality Electric Shock Roasting and baking machine operators, food
Back to Top

Thank You for Visiting Our Website

You are exiting the Department of Labor's Web server.

The Department of Labor does not endorse, takes no responsibility for, and exercises no control over the linked organization or its views, or contents, nor does it vouch for the accuracy or accessibility of the information contained on the destination server. The Department of Labor also cannot authorize the use of copyrighted materials contained in linked Web sites. Users must request such authorization from the sponsor of the linked Web site. Thank you for visiting our site. Please click the button below to continue.