Inspection Detail
Inspection: 1221747.015 - Keith Phillips
Inspection Information - Office: Department Of Labor, Licensing, And Regulation Division Of Labor And Industry Maryland Occupational Safety And Health
Site Address:
Keith Phillips
1122 Sunrise Beach Road
Crownsville, MD 21032
Mailing Address:
257 Arundel Road, Pasadena, MD 21122
Union Status: NonUnion
SIC:
NAICS: 237130/Power and Communication Line and Related Structures Construction
Inspection Type: Fat/Cat
Scope: Partial
Advanced Notice: N
Ownership: Private
Safety/Health: Safety
Close Conference: 07/13/2017
Emphasis: S:Electric
Case Closed: 08/29/2017
Type | Activity Nr | Safety | Health |
---|---|---|---|
Accident | 1197532 |
Violations/Penalties | Serious | Willful | Repeat | Other | Unclass | Total |
---|---|---|---|---|---|---|
Initial Violations | 1 | 1 | ||||
Current Violations | 1 | 1 | ||||
Initial Penalty | $2,875 | $0 | $0 | $0 | $0 | $2,875 |
Current Penalty | $2,875 | $0 | $0 | $0 | $0 | $2,875 |
FTA Penalty | $0 | $0 | $0 | $0 | $0 | $0 |
# | Citation ID | Citaton Type | Standard Cited | Issuance Date | Abatement Due Date | Current Penalty | Initial Penalty | FTA Penalty | Contest | Latest Event | Note |
---|---|---|---|---|---|---|---|---|---|---|---|
1. | 01001 | Serious | 19100268 C | 07/25/2017 | 08/25/2017 | $2,875 | $2,875 | $0 | Z - Issued |
Investigation Summary
At approximately 10:45 a.m. on March 30, 2017, Employee #1 and coworkers were installing approximately 1,050 feet of cable lines spanning five pre-existing utility poles. The work required all vines and other natural growth to be removed so the lines could be properly lashed to the support cable. Employee #1 was in a bucket truck and pulled the new line into position, referred to as jigging it out. A coworker, foreman, assisted in the operation by climbing trees and cutting vines away from the support cable ahead of the bucket truck. They were working on clearing the sticks and vines at a height of the communication lines, ranging between 14.25 and 15.75 foot high. A grounded neutral conductor was sagging into the area of the communication lines at a height of 14.84. The high voltage power lines consisted of three phases. The A-phase line was located 25.67 foot above the ground, the B-phase line was located 25.67 foot above the ground, and the C-phase line was located 25 feet 8 inches above the ground. The phase-to-phase voltage was 13,200 volts and the phase to ground voltage was 7620 volts. The bucket truck, a Chevrolet work truck had an un-insulated lift with a maximum working platform level of 28 foot. The coworker climbed down out of the tree and was walking near the truck and never saw Employee #1 extend the boom to elevate the bucket higher than the communication lines. Employee #1 extended the boom and elevated the bucket too far above the communication lines to a point of making direct contact with the C-phase power line. According to coworkers there was a loud buzzing noise and there were possibly two flashes. The bucket was comprised of fiberglass but attached to it was a metal control box and the boom was un-insulated. The back of Employee #1's head contacted the C-Phase power line. The electricity traveled through Employee #1 and the boom of the truck to the ground. Employee #1 was electrocuted with burns to his upper body from fire.
Keywords: Aerial Lift, Burn, Electrical, Elevated Work Platform, Emergency Response, Fire, Head, Power Lines, Struck By
# | Inspection | Age | Sex | Degree of Injury | Nature of Injury | Occupation |
---|---|---|---|---|---|---|
1 | 1221747.015 | 39 | M | Fatality | Telecomm: Line Installers And Repairers |