Powered by GoogleTranslate

Inspection Detail

Case Status: CLOSED

Inspection: 1221599.015 - Garaventa Enterprises Inc

Inspection Information - Office: American Canyon District Office

 

Inspection Nr: 1221599.015
Report ID: 0950615
Date Opened: 03/29/2017

Site Address:
Garaventa Enterprises Inc
1151 Loveridge Road
Pittsburg, CA 94565

Mailing Address:
P. O. Box 5397, Concord, CA 94524

Union Status: Union

SIC:

NAICS: 562111/Solid Waste Collection


Inspection Type: Accident

Scope: Partial

Advanced Notice: N

Ownership: Private

Safety/Health: Safety

Close Conference: 07/27/2017

Emphasis:

Case Closed: 01/12/2018


Related Activity
Type Activity Nr Safety Health
Accident 1196618
Case Status: CLOSED
Violation Summary
Violations/Penalties Serious Willful Repeat Other Unclass Total
Initial Violations 2 2 4
Current Violations 1 3 4
Initial Penalty $20,700 $0 $0 $600 $0 $21,300
Current Penalty $9,000 $0 $0 $3,300 $0 $12,300
FTA Penalty $0 $0 $0 $0 $0 $0

Violation Items
# Citation ID Citaton Type Standard Cited Issuance Date Abatement Due Date Current Penalty Initial Penalty FTA Penalty Contest Latest Event Note
1. 01001 Other 5194(H)(2) 08/02/2017 $300 $300 $0 Z - Issued  
2. 01002 Other 3203(A)(6)(A) 08/02/2017 $300 $300 $0 Z - Issued  
3. 02001 Other 3328(B) 08/02/2017 $2,700 $2,700 $0 09/15/2017 F - Formal Settlement  
4. 03001 Serious 4848(A) 08/02/2017 $9,000 $18,000 $0 09/15/2017 F - Formal Settlement  

Investigation Summary

Investigation Nr: 94363.015
Event: 03/28/2017
Employee is welding drum bolt and receives burns on upper bo

At 3:20 p.m. on March 28, 2017, an employee was MIG welding on a drum bolt located on the yolk of a wood hog that was still contaminated by a combustible gear hydraulic fluid residue. The fluid residue burst into flames and the employee received burns on their upper body and chest area.

Keywords: Burn, Combustible Liquid, Hydraulic Fluid

Investigated Inspection
# Inspection Age Sex Degree of Injury Nature of Injury Occupation
1 1221599.015 42 M Hospitalized injury Mechanical controls and valve repairers
Back to Top

Thank You for Visiting Our Website

You are exiting the Department of Labor's Web server.

The Department of Labor does not endorse, takes no responsibility for, and exercises no control over the linked organization or its views, or contents, nor does it vouch for the accuracy or accessibility of the information contained on the destination server. The Department of Labor also cannot authorize the use of copyrighted materials contained in linked Web sites. Users must request such authorization from the sponsor of the linked Web site. Thank you for visiting our site. Please click the button below to continue.

Close