Inspection Detail
Inspection: 122042971 - Superior Masonry Builders Inc.
Inspection Information - Office: Milwaukee Area Office
Site Address:
Superior Masonry Builders Inc.
16220 West Bluemound Road
Brookfield, WI 53007
Mailing Address:
12699 West Arden Place, Butler, WI 53007
Union Status: Union
SIC:1741
NAICS: 0
Inspection Type: Accident
Scope: Complete
Advanced Notice: N
Ownership: Private
Safety/Health: Safety
Close Conference: 07/19/1996
Planning Guide: Safety-Construction
Emphasis:
Case Closed: 03/07/2008
Type | Activity Nr | Safety | Health |
---|---|---|---|
Accident | 360407704 |
Violations/Penalties | Serious | Willful | Repeat | Other | Unclass | Total |
---|---|---|---|---|---|---|
Initial Violations | 2 | 1 | 3 | |||
Current Violations | 2 | 2 | ||||
Initial Penalty | $14,000 | $70,000 | $0 | $0 | $0 | $84,000 |
Current Penalty | $14,000 | $0 | $0 | $0 | $0 | $14,000 |
FTA Penalty | $0 | $0 | $0 | $0 | $0 | $0 |
# | Citation ID | Citaton Type | Standard Cited | Issuance Date | Abatement Due Date | Current Penalty | Initial Penalty | FTA Penalty | Contest | Latest Event | Note |
---|---|---|---|---|---|---|---|---|---|---|---|
1. | 01001 | Serious | 19260021 B02 | 07/24/1996 | 09/10/1996 | $7,000 | $7,000 | $0 | 07/30/1996 | F - Formal Settlement | |
2. | 01002 | Serious | 19260451 A03 | 07/24/1996 | 07/30/1996 | $7,000 | $7,000 | $0 | 07/30/1996 | F - Formal Settlement | |
3. | 02001 | Serious | 19260451 A15 | 07/24/1996 | 07/30/1996 | $7,000 | $70,000 | $0 | 07/30/1996 | F - Formal Settlement | Citation has been deleted. |
Investigation Summary
At approximately 11:30 a.m. on February 7, 1996, Employees #1 through #5, bricklayers, and Employees #6 and #7, laborers, were veneering a concrete block wall with brick while standing on the platform of a 16 tower (8 pairs) Morgan scaffold approximately 24 ft from the ground. The scaffold towers were erected to a height of 27 ft in three 9 ft sections. Seven masonry wall anchors were placed in the veneer portion of the wall 16 ft above the ground at 15 ft horizontal intervals (every other tower). Because of a lack of stiff arm braces, only five of the seven anchors were used, leaving four towers at the north end unanchored. Three anchors on the north end were concrete block to brick wall ties using #6 wire and were not designed for this type of application. The typical notched flat stock anchors were not installed properly because regular non-cut nails were used. The employer also failed to anchor every tower at 9 ft vertical intervals as required for enclosed scaffolds. The working platform was enclosed with a plastic canopy open to the wall on the west end of the scaffold. As the platform was raised above the offset roof eave line, a 32 mph wind gust from the west-southwest tipped the north tower east. As the tower fell, it struck thirteen other towers that all collapsed. All five anchors in use were pulled from the wall. Employees #1 through #7 fell to the ground, sustaining fractures to the head, face, pelvis, ankle, knee, and arm, as well as lacerations and bruises. They were hospitalized.
Keywords: ANCHOR, FRACTURE, HIGH WIND, UNSECURED, WORK RULES, CONSTRUCTION, SCAFFOLD COLLAPSE, BRACING, TOWER, SCAFFOLD
# | Inspection | Age | Sex | Degree of Injury | Nature of Injury | Occupation |
---|---|---|---|---|---|---|
1 | 122042971 | Hospitalized injury | Cut/Laceration | Brickmasons and stonemasons | ||
2 | 122042971 | Hospitalized injury | Cut/Laceration | Brickmasons and stonemasons | ||
3 | 122042971 | Hospitalized injury | Bruise/Contus/Abras | Brickmasons and stonemasons | ||
4 | 122042971 | Hospitalized injury | Fracture | Construction trades, n.e.c. | ||
5 | 122042971 | Hospitalized injury | Fracture | Construction trades, n.e.c. | ||
6 | 122042971 | Hospitalized injury | Fracture | Brickmasons and stonemasons | ||
7 | 122042971 | Hospitalized injury | Fracture | Brickmasons and stonemasons |