Inspection Detail
Inspection: 1219602.015 - Bock Water Heaters, Inc.
Inspection Information - Office: Madison Area Office
Site Address:
Bock Water Heaters, Inc.
110 S. Dickinson St.
Madison, WI 53703
Mailing Address:
110 S. Dickinson St., Madison, WI 53703
Union Status: NonUnion
SIC:
NAICS: 333318
Inspection Type: Referral
Scope: Partial
Advanced Notice: N
Ownership: Private
Safety/Health: Safety
Close Conference: 03/24/2017
Emphasis: N:Amputate
Case Closed: 04/26/2017
| Type | Activity Nr | Safety | Health |
|---|---|---|---|
| Referral | 1193028 | Yes |
| Violations/Penalties | Serious | Willful | Repeat | Other | Unclass | Total |
|---|---|---|---|---|---|---|
| Initial Violations | 1 | 1 | ||||
| Current Violations | 1 | 1 | ||||
| Initial Penalty | $8,873 | $0 | $0 | $0 | $0 | $8,873 |
| Current Penalty | $4,753 | $0 | $0 | $0 | $0 | $4,753 |
| FTA Penalty | $0 | $0 | $0 | $0 | $0 | $0 |
| # | Citation ID | Citaton Type | Standard Cited | Issuance Date | Abatement Due Date | Current Penalty | Initial Penalty | FTA Penalty | Contest | Latest Event | Note |
|---|---|---|---|---|---|---|---|---|---|---|---|
| 1. | 01001 | Serious | 19100212 A03 II | 04/05/2017 | $4,753 | $8,873 | $0 | I - Informal Settlement |
Investigation Summary
At 7:10 a.m. on March 17, 2017, an employee was operating the Wysong roll former (Serial No. PR17-142) at a company that produces commercial water heaters, and he was forming heat jackets for the water heaters. The employee reached into the dies of the roll former and suffered several finger fractures to three fingers on his left hand. The employee was hospitalized and surgery was performed to repair the employee's fractures.
Keywords: Caught In, Finger, Fracture, Machine Guarding, Roller--Mach/Part
| # | Inspection | Age | Sex | Degree of Injury | Nature of Injury | Occupation |
|---|---|---|---|---|---|---|
| 1 | 1219602.015 | 31 | M | Hospitalized injury | Fabricating machine operators, n.e.c. |