Powered by GoogleTranslate

Inspection Detail

Inspection: 1219401 - Mcabee Construction Inc.

Inspection Information - Office: Savannah Area Office

 

Inspection Nr: 1219401
Report ID: 0418400
Date Opened: 02/08/1985

Site Address:
Mcabee Construction Inc.
Hwy 31 Owens-Illinois Plant
Clyattville, GA 31604

Mailing Address:
P. O. Drawer 1460, Tuscaloosa, AL 35403

Union Status: Union

SIC:1791

NAICS: 0 


Inspection Type: Unprog Rel

Scope: Partial

Advanced Notice: N

Ownership: Private

Safety/Health: Safety

Close Conference: 02/14/1985

Planning Guide: Safety-Construction

Emphasis:

Case Closed: 04/23/1985


Related Activity
Type Activity Nr Safety Health
Referral 900867714 Yes
Violation Summary
Violations/Penalties Serious Willful Repeat Other Unclass Total
Initial Violations 1 1
Current Violations 1 1
Initial Penalty $0 $0 $0 $0 $0 $0
Current Penalty $0 $0 $0 $0 $0 $0
FTA Penalty $0 $0 $0 $0 $0 $0

Violation Items
# Citation ID Citaton Type Standard Cited Issuance Date Abatement Due Date Current Penalty Initial Penalty FTA Penalty Contest Latest Event Note
1. 01001 Other 19260500 F04 III 03/21/1985 03/24/1985 $0 $0 $0 -  

Investigation Summary

Investigation Nr: 14348361
Event: 02/04/1985
TANK RUPTURED AND SPEWED HOT LIQUOR ON EMPLOYEES

ON FEBRUARY 4, 1885, AT 9:30 AM, THE PRIME CONTRACTOR WAS RUNNING AN EXPERIMENT, BY COMPUTER, ON THE #10 DIGESTER. A SUBCONTRACTOR AND A PLANT EMPLOYEE WERE ASSISTING. A BLOW LINE PLUGGED. AIR AND STEAM FAILED TO CLEAR THE LINE. A SUBCONTRACTOR EMPLOYEE PULLED THE CARDS FROM THE BAILEY CONTROL NET 90 DISTRIBUTIVE CONTROL SYSTEM (COMPUTER). REMOVAL OF THE CARDS CAUSED THREE VALVES TO OPEN. THE OPENING OF TWO OF THESE VALVES CAUSED THE WARM LIQUOR ACCUMULATOR TANK TO OVERPRESSURIZE. THE TANK RUPTURED AT THE TOP WELDED SEAMS, BLOWING HOT BLACK LIQUOR ONTO EMPLOYEES #1 THROUGH #9, WHO WERE WORKING IN PROXIMITY TO THE TANK. THE CARDS SHOULD NOT HAVE BEEN PULLED AND THEN PLUGGED BACK IN WITHOUT SETTING THE DEFAULT VALVE FOR "CLOSED". CONTRACTOR PERSONNEL WORKING ON OR AROUND THE TANK SHOULD HAVE BEEN NOTIFIED OF THE EXPERIMENT AND INSTRUCTED TO TAKE THE REQUIRED ACTIONS TO PROTECT THEMSELVES.

Keywords: TANK, BURN, WORK RULES, CONSTRUCTION, RUPTURE, HIGH PRESSURE

Investigated Inspection
# Inspection Age Sex Degree of Injury Nature of Injury Occupation
1 1219401 Hospitalized injury Burn(Chemical) Occupation not reported
2 1219401 Fatality Burn(Chemical) Occupation not reported
Back to Top

Thank You for Visiting Our Website

You are exiting the Department of Labor's Web server.

The Department of Labor does not endorse, takes no responsibility for, and exercises no control over the linked organization or its views, or contents, nor does it vouch for the accuracy or accessibility of the information contained on the destination server. The Department of Labor also cannot authorize the use of copyrighted materials contained in linked Web sites. Users must request such authorization from the sponsor of the linked Web site. Thank you for visiting our site. Please click the button below to continue.

Close