Inspection Detail
Inspection: 121937965 - Seibert Powder Coatings, Inc.
Inspection Information - Office: Cleveland Area Office
Site Address:
Seibert Powder Coatings, Inc.
11110 Berea Road
Cleveland, OH 44102
Mailing Address:
, , 00000
Union Status: NonUnion
SIC:3479
NAICS: 0
Inspection Type: Complaint
Scope: Complete
Advanced Notice: N
Ownership: Private
Safety/Health: Health
Close Conference: 11/06/1995
Emphasis:
Case Closed: 10/01/1996
Type | Activity Nr | Safety | Health |
---|---|---|---|
Complaint | 77142214 | Yes |
Violations/Penalties | Serious | Willful | Repeat | Other | Unclass | Total |
---|---|---|---|---|---|---|
Initial Violations | 7 | 4 | 11 | |||
Current Violations | 6 | 2 | 8 | |||
Initial Penalty | $15,000 | $0 | $0 | $0 | $0 | $15,000 |
Current Penalty | $11,500 | $0 | $0 | $0 | $0 | $11,500 |
FTA Penalty | $0 | $0 | $0 | $0 | $0 | $0 |
# | Citation ID | Citaton Type | Standard Cited | Issuance Date | Abatement Due Date | Current Penalty | Initial Penalty | FTA Penalty | Contest | Latest Event | Note |
---|---|---|---|---|---|---|---|---|---|---|---|
1. | 01001 | Serious | 19100095 B01 | 11/20/1995 | 08/15/1996 | $1,250 | $1,250 | $0 | P - Petition to Mod Abatement | ||
2. | 01002A | Serious | 19100095 D01 | 11/20/1995 | 01/31/1996 | $1,250 | $1,250 | $0 | P - Petition to Mod Abatement | ||
3. | 01002B | Serious | 19100095 G06 | 11/20/1995 | 01/31/1996 | $0 | $0 | $0 | P - Petition to Mod Abatement | ||
4. | 01002C | Serious | 19100095 K01 | 11/20/1995 | 01/31/1996 | $0 | $0 | $0 | P - Petition to Mod Abatement | ||
5. | 01002D | Serious | 19100095 L01 | 11/20/1995 | 01/31/1996 | $0 | $0 | $0 | P - Petition to Mod Abatement | ||
6. | 01003A | Serious | 19100147 C04 I | 11/20/1995 | 01/31/1996 | $1,250 | $1,250 | $0 | P - Petition to Mod Abatement | ||
7. | 01003B | Serious | 19100147 C07 I | 11/20/1995 | 01/31/1996 | $0 | $0 | $0 | P - Petition to Mod Abatement | ||
8. | 01004A | Serious | 19101200 E01 | 11/20/1995 | 01/31/1996 | $750 | $750 | $0 | P - Petition to Mod Abatement | ||
9. | 01004B | Serious | 19101200 H | 11/20/1995 | 01/31/1996 | $0 | $0 | $0 | P - Petition to Mod Abatement | ||
10. | 01005A | Serious | 19260352 D | 11/20/1995 | 11/26/1995 | $3,500 | $3,500 | $0 | I - Informal Settlement | Citation has been deleted. | |
11. | 01005B | Serious | 19260352 E | 11/20/1995 | 11/26/1995 | $0 | $0 | $0 | I - Informal Settlement | Citation has been deleted. | |
12. | 01006 | Serious | 19260352 C | 11/20/1995 | 11/26/1995 | $3,500 | $3,500 | $0 | - | ||
13. | 01007 | Serious | 19260352 I | 11/20/1995 | 11/26/1995 | $3,500 | $3,500 | $0 | - | ||
14. | 02001 | Other | 19040002 A | 11/20/1995 | 01/31/1996 | $0 | $0 | $0 | I - Informal Settlement | ||
15. | 02002 | Other | 19100020 G02 | 11/20/1995 | 01/31/1996 | $0 | $0 | $0 | P - Petition to Mod Abatement | ||
16. | 02003 | Other | 19100132 D02 | 11/20/1995 | 01/31/1996 | $0 | $0 | $0 | P - Petition to Mod Abatement | Citation has been deleted. | |
17. | 02004 | Other | 19100132 F04 | 11/20/1995 | 01/31/1996 | $0 | $0 | $0 | P - Petition to Mod Abatement | Citation has been deleted. |
Investigation Summary
Employees #1 and #2 and a coworker had been assigned to cut up six 5 ft by 5 ft by 8 ft steel tanks in a small upper level storage room using an oxygen/propane cutting torch. The three workers had been informed that the tanks were "okay to burn." Employee #1 had just arrived where the cutting was taking place, having just tried to get more fire extinguishing equipment since the available portable extinguisher had run out from other incipient fires that day. The third worker soon left the area as Employees #1 and #2 continued cutting the first tank. Within the next few minutes Employee #2 observed a small fire under the back tank, but it could not be put out since no other fire extinguishing equipment was available. Soon after observing this fire, Employees #1 and #2 heard a whoosh and then an explosion. Employee #1 was blown approximately 12 to 15 ft to the lower level. Employee #2 sustained burns to both arms from his wrists to shoulders. Both were hospitalized for treatment. Employee #2 was released four days later, but Employee #1 was held in intensive care for over six weeks. The work site had been a paint and finish manufacturer at one time, but it had been out of production for nearly 20 years and was being gutted and remodeled for a new manufacturer at the time of the accident. The tanks apparently had not been used in over 20 years, but a residue containing hazardous material was still present. The tanks had not been properly cleaned, inerted, ventilated, or tested before being cut.
Keywords: FLAMMABLE VAPORS, WORK RULES, EXPLOSION, TANK, BURN, FIRE, CONSTRUCTION, PROPANE TORCH, ARM, CUTTING AND BURNING
# | Inspection | Age | Sex | Degree of Injury | Nature of Injury | Occupation |
---|---|---|---|---|---|---|
1 | 121937965 | Occupation Not Listed |