Powered by GoogleTranslate

Inspection Detail

Case Status: CLOSED

Inspection: 1219196.015 - S. J. Conner & Sons, Inc.

Inspection Information - Office: Va-E-Roanoke (Regional Office) -Health 0355123

 

Inspection Nr: 1219196.015
Report ID: 0355123
Date Opened: 03/23/2017

Site Address:
S. J. Conner & Sons, Inc.
3531 Peters Creek Road
Roanoke, VA 24012

Mailing Address:
1639 Seibel Drive, Ne, Roanoke, VA 24012

Union Status: NonUnion

SIC:

NAICS: 238220/ Plumbing, Heating, and Air-Conditioning Contractors


Inspection Type: Referral

Scope: Partial

Advanced Notice: N

Ownership: Private

Safety/Health: Health

Close Conference: 05/05/2017

Emphasis:

Case Closed: 06/05/2017


Related Activity
Type Activity Nr Safety Health
Referral 1194404 Yes
Case Status: CLOSED
Violation Summary
Violations/Penalties Serious Willful Repeat Other Unclass Total
Initial Violations 1 1
Current Violations 1 1
Initial Penalty $2,205 $0 $0 $0 $0 $2,205
Current Penalty $1,544 $0 $0 $0 $0 $1,544
FTA Penalty $0 $0 $0 $0 $0 $0

Violation Items
# Citation ID Citaton Type Standard Cited Issuance Date Abatement Due Date Current Penalty Initial Penalty FTA Penalty Contest Latest Event Note
1. 01001A Serious 19101000 A02 05/10/2017 $1,544 $2,205 $0 I - Informal Settlement  
2. 01001B Serious 19101000 E 05/10/2017 $0 $0 $0 I - Informal Settlement  

Investigation Summary

Investigation Nr: 95203.015
Event: 03/23/2017
Employees become ill after exposure to exhaust from gas powe

At approximately 11:30 a.m. on March 23, 2017, two employees were cutting through a concrete floor to replace a sewer pipe inside a hallway of a condominium complex. The employees were using a gas powered concrete saw. The concrete saw was equipped with a Foley Industrial Engine Exhaust Purifier which was supposed to reduce carbon monoxide to a safe level. The exhaust purifier which was a bolt on a catalytic converter would only reduce carbon monoxide levels to 5,000 ppm per information from the manufacturer's website information. The employees began to experience light headedness, headaches, disorientation, and tingling in hands from exposure to the exhaust from the gas powered concrete saw. The employees were exposed to carbon monoxide levels which exceeded 50 ppm as an 8 hour time weighted after just 30 minutes of exposure. The fire department measured carbon monoxide levels of over 300 ppm. Carboxyhemoglobin levels two hours after exposure were 19.5% and 18.2%. The employees did not lose consciousness and were not hospitalized.

Keywords: Asphyxiated, Carbon Monoxide, Chemical, Exhaust Fumes, Inhalation, Saw

Investigated Inspection
# Inspection Age Sex Degree of Injury Nature of Injury Occupation
1 1219196.015 44 M Non Hospitalized injury Plumbers, pipefitters and steamfitters
Back to Top

Thank You for Visiting Our Website

You are exiting the Department of Labor's Web server.

The Department of Labor does not endorse, takes no responsibility for, and exercises no control over the linked organization or its views, or contents, nor does it vouch for the accuracy or accessibility of the information contained on the destination server. The Department of Labor also cannot authorize the use of copyrighted materials contained in linked Web sites. Users must request such authorization from the sponsor of the linked Web site. Thank you for visiting our site. Please click the button below to continue.

Close