Powered by GoogleTranslate

Inspection Detail

Inspection: 121917934 - Electro-Motive Diesel

Inspection Information - Office: Chicago South Area Office

 

Inspection Nr: 121917934
Report ID: 0521700
Date Opened: 09/01/1999

Site Address:
Electro-Motive Diesel
9301 W. 55th Street
La Grange, IL 60525

Mailing Address:
, , 00000

Union Status: Union

SIC:3743

NAICS: 0 


Inspection Type: Complaint

Scope: Partial

Advanced Notice: N

Ownership: Private

Safety/Health: Safety

Close Conference: 10/08/1999

Emphasis: N:Pwrpress, S:Amputations

Case Closed: 04/26/2000


Related Activity
Type Activity Nr Safety Health
Complaint 202709085 Yes
Violation Summary
Violations/Penalties Serious Willful Repeat Other Unclass Total
Initial Violations 3 1 2 6
Current Violations 3 2 1 6
Initial Penalty $8,000 $70,000 $0 $0 $0 $78,000
Current Penalty $6,500 $0 $0 $0 $50,000 $56,500
FTA Penalty $0 $0 $0 $0 $0 $0

Violation Items
# Citation ID Citaton Type Standard Cited Issuance Date Abatement Due Date Current Penalty Initial Penalty FTA Penalty Contest Latest Event Note
1. 01001 Serious 19100022 A01 10/20/1999 10/25/1999 $750 $1,500 $0 11/16/1999 F - Formal Settlement  
2. 01002 Serious 19100147 C07 IA 10/20/1999 11/16/1999 $5,000 $5,000 $0 11/16/1999 F - Formal Settlement  
3. 01003 Serious 19100212 A01 10/20/1999 10/25/1999 $750 $1,500 $0 11/16/1999 F - Formal Settlement  
4. 02001 Unclass 19100217 C02 IA 10/20/1999 10/25/1999 $50,000 $70,000 $0 11/16/1999 F - Formal Settlement  
5. 03001 Other 19100217 E01 II 10/20/1999 11/23/1999 $0 $0 $0 11/16/1999 F - Formal Settlement  
6. 03002 Other 19100217 G 10/20/1999 11/16/1999 $0 $0 $0 11/16/1999 F - Formal Settlement  

Investigation Summary

Investigation Nr: 200030732
Event: 08/06/1999
Employee's hand injured when caught in power press

Employee #1, a temporary worker, was setting up a die in a Clearing 32 ton part-revolution mechanical power press when he inadvertently cycled the press with the foot-operated control. His right hand was in the die area and sustained serious injuries, for which Employee #1 underwent several operations to repair damage to his hand and fingers. Apparently, the press's guarding and gates were not interlocked, thus allowing Employee #1's hand to be in the die area.

Keywords: POWER PRESS, WORK RULES, INTERLOCK, CRUSHED, DIE GUARD, POINT OF OPERATION, FOOT-POWERED PRESS, PRESS OPERATOR, HAND, PRESS

Investigated Inspection
# Inspection Age Sex Degree of Injury Nature of Injury Occupation
1 121917934 Hospitalized injury Dislocation Occupation not reported
Back to Top

Thank You for Visiting Our Website

You are exiting the Department of Labor's Web server.

The Department of Labor does not endorse, takes no responsibility for, and exercises no control over the linked organization or its views, or contents, nor does it vouch for the accuracy or accessibility of the information contained on the destination server. The Department of Labor also cannot authorize the use of copyrighted materials contained in linked Web sites. Users must request such authorization from the sponsor of the linked Web site. Thank you for visiting our site. Please click the button below to continue.

Close