Powered by GoogleTranslate

Inspection Detail

Inspection: 121908461 - Hitwell Surveys, Inc.

Inspection Information - Office: Columbus Area Office

 

Inspection Nr: 121908461
Report ID: 0522500
Date Opened: 06/28/1994

Site Address:
Hitwell Surveys, Inc.
Jackson Twp. Rd. 10, Ohio Power Co. Lease #J-19-61
Crooked Tree, OH 45727

Mailing Address:
P.O. Box 43, Parkersburg, WV 26102

Union Status: NonUnion

SIC:1389

NAICS: 0 


Inspection Type: Referral

Scope: Complete

Advanced Notice: N

Ownership: Private

Safety/Health: Safety

Close Conference: 06/28/1994

Emphasis:

Case Closed: 08/12/1994


Related Activity
Type Activity Nr Safety Health
Referral 901551788 Yes

Investigation Summary

Investigation Nr: 170094080
Event: 06/28/1994
Employees burned when well explodes during service

Employees #1, #2, and #3 were attempting to remove a metal water tank plug that was threaded onto the top of the well when it suddenly flew off, striking Employee #1 in the face. An explosion and fire occurred, causing burn injuries to Employees #1 through #3.

Keywords: WELL, EXPLOSION, BURN, MAINTENANCE, FIRE, OIL WELL SERVICING, STRUCK BY, FACE

Investigated Inspection
# Inspection Age Sex Degree of Injury Nature of Injury Occupation
1 121908461 Non Hospitalized injury Burn/Scald(Heat) Occupation not reported
2 121908461 Non Hospitalized injury Burn/Scald(Heat) Occupation not reported
Back to Top

Thank You for Visiting Our Website

You are exiting the Department of Labor's Web server.

The Department of Labor does not endorse, takes no responsibility for, and exercises no control over the linked organization or its views, or contents, nor does it vouch for the accuracy or accessibility of the information contained on the destination server. The Department of Labor also cannot authorize the use of copyrighted materials contained in linked Web sites. Users must request such authorization from the sponsor of the linked Web site. Thank you for visiting our site. Please click the button below to continue.

Close