Inspection Detail
Inspection: 1217580.015 - Precision Industrial Maintenance, Inc.
Inspection Information - Office: Fairview Heights Area Office
Site Address:
Precision Industrial Maintenance, Inc.
Center Ethanol Plant 231 Monsanto Avenue
Sauget, IL 62201
Mailing Address:
8314 West Main Street, Belleville, IL 62223
Union Status: Union
SIC:
NAICS: 238290/Other Building Equipment Contractors
Inspection Type: Referral
Scope: Partial
Advanced Notice: N
Ownership: Private
Safety/Health: Safety
Close Conference: 06/29/2017
Emphasis:
Case Closed: 08/08/2017
Type | Activity Nr | Safety | Health |
---|---|---|---|
Referral | 1191246 | Yes |
Violations/Penalties | Serious | Willful | Repeat | Other | Unclass | Total |
---|---|---|---|---|---|---|
Initial Violations | 2 | 2 | ||||
Current Violations | 2 | 2 | ||||
Initial Penalty | $5,794 | $0 | $0 | $0 | $0 | $5,794 |
Current Penalty | $3,766 | $0 | $0 | $0 | $0 | $3,766 |
FTA Penalty | $0 | $0 | $0 | $0 | $0 | $0 |
# | Citation ID | Citaton Type | Standard Cited | Issuance Date | Abatement Due Date | Current Penalty | Initial Penalty | FTA Penalty | Contest | Latest Event | Note |
---|---|---|---|---|---|---|---|---|---|---|---|
1. | 01001 | Serious | 19100147 C04 II | 07/10/2017 | 08/03/2017 | $1,883 | $2,897 | $0 | I - Informal Settlement | ||
2. | 01002 | Serious | 19100147 D | 07/10/2017 | 08/03/2017 | $1,883 | $2,897 | $0 | I - Informal Settlement |
Investigation Summary
At approximately 10:00 a.m. on March 14, 2017, an employee and two coworkers worked to open the tube side of the reboiler unit for cleaning operations. The work was performed inside a two story building at an ethanol plant. The reboiler was a Paul Mueller Company Model N43891, Serial Number 364723. The employer had informed the employee and the coworkers who were removing both the nuts and the bolts for the opening that hot water would be released. There were no procedures to isolate or otherwise render the hot water safe. The employee was standing next to the tube side as the bolt removal was finished when the reboiler opened releasing 150 degree water onto the employee. The employee received second degree burns to the shoulders, thigh, arms, hips and the back for which he was hospitalized.
Keywords: Boiler, Flowing Material, Heat, Lockout/Tagout, Material Handling, Struck By
# | Inspection | Age | Sex | Degree of Injury | Nature of Injury | Occupation |
---|---|---|---|---|---|---|
1 | 1217580.015 | 42 | M | Hospitalized injury | Carpenters |