Powered by GoogleTranslate

Inspection Detail

Case Status: CLOSED

Inspection: 1214667.015 - Stewart Tubular Products, Llc

Inspection Information - Office: Houston North Area Office

 

Inspection Nr: 1214667.015
Report ID: 0626600
Date Opened: 03/03/2017

Site Address:
Stewart Tubular Products, Llc
5951 N. Houston Rosslyn Road
Houston, TX 77091

Mailing Address:
5951 N. Houston Rosslyn Road, Houston, TX 77091

Union Status: NonUnion

SIC:

NAICS: 333132/Oil and Gas Field Machinery and Equipment Manufacturing


Inspection Type: Referral

Scope: Partial

Advanced Notice: N

Ownership: Private

Safety/Health: Health

Close Conference: 03/03/2017

Emphasis:

Case Closed: 03/03/2017


Related Activity
Type Activity Nr Safety Health
Referral 1188145 Yes
Case Status: CLOSED

Investigation Summary

Investigation Nr: 93612.015
Event: 03/02/2017
Employee removing part from lathe has thumb amputated

At 8:39 a.m. on March 2, 2017, Employee #1, employed by a tubular parts manufacturer, was removing a finished part from a CNC lathe. As he grabbed the part, he inadvertently hit a foot control that activated a hold down ram arm. The ram arm reclosed on the part. Employee #1's thumb was in the pinch point. Emergency services were called, and Employee #1 was transported to the hospital.

Keywords: Amputation, Caught In, Finger, Foot Control, Lathe, Material Handling, Pinned, Thumb

Investigated Inspection
# Inspection Age Sex Degree of Injury Nature of Injury Occupation
1 1214667.015 31 M Non Hospitalized injury
Back to Top

Thank You for Visiting Our Website

You are exiting the Department of Labor's Web server.

The Department of Labor does not endorse, takes no responsibility for, and exercises no control over the linked organization or its views, or contents, nor does it vouch for the accuracy or accessibility of the information contained on the destination server. The Department of Labor also cannot authorize the use of copyrighted materials contained in linked Web sites. Users must request such authorization from the sponsor of the linked Web site. Thank you for visiting our site. Please click the button below to continue.

Close