Inspection Detail
Inspection: 1214193.015 - Control Devices, Llc
Inspection Information - Office: Saint Louis Area Office
Site Address:
Control Devices, Llc
1555 Larkin Williams Road
Fenton, MO 63026
Mailing Address:
1555 Larkin Williams Road, Fenton, MO 63026
Union Status: NonUnion
SIC:
NAICS: 332911/Industrial Valve Manufacturing
Inspection Type: Referral
Scope: Partial
Advanced Notice: N
Ownership: Private
Safety/Health: Safety
Close Conference: 02/28/2017
Emphasis: N:Amputate
Case Closed: 04/24/2017
| Type | Activity Nr | Safety | Health |
|---|---|---|---|
| Referral | 1185336 | Yes |
Investigation Summary
At approximately 7:30 a.m. on February 22, 2017, Employee #1 was operating a CNC machine when he used his hand to unjam a piece of stock. Employee #1's hand was amputated and he was hospitalized.
Keywords: Amputation, Caught By, Hand, Jammed, Lockout/Tagout
| # | Inspection | Age | Sex | Degree of Injury | Nature of Injury | Occupation |
|---|---|---|---|---|---|---|
| 1 | 1214193.015 | 52 | M | Hospitalized injury | Machine operators, not specified |
Translate