Inspection Detail
Inspection: 1213708.015 - Easypak, Llc
Inspection Information - Office: Springfield Area Office
Site Address:
Easypak, Llc
24 Jytek Drive
Leominster, MA 01453
Mailing Address:
24 Jytek Drive, Leominster, MA 01453
Union Status: NonUnion
SIC:
NAICS: 326121/Unlaminated Plastics Profile Shape Manufacturing
Inspection Type: Referral
Scope: Partial
Advanced Notice: N
Ownership: Private
Safety/Health: Safety
Close Conference: 02/28/2017
Emphasis: N:Amputate
Case Closed: 03/31/2017
| Type | Activity Nr | Safety | Health |
|---|---|---|---|
| Referral | 1186149 | Yes |
Investigation Summary
At approximately 8:15 a.m. on February 25, 2017, Employee #1 climbed onto a mounting platform of a Motan Dosing\Mixer Spectrocolor V mixer to check the vacuum hoses for air movement. As he came down the platform, he caught his hand on a protruding machine bolt that was part of the machine. The bolt caught his ring finger and the weight of his body and downward movement caused his wedding band to cut and stretch his finger to the point of amputation at the first knuckle. Employee #1 was hospitalized.
Keywords: Amputation, Caught By, Finger, Ring
| # | Inspection | Age | Sex | Degree of Injury | Nature of Injury | Occupation |
|---|---|---|---|---|---|---|
| 1 | 1213708.015 | 42 | M | Hospitalized injury | Machine operators, not specified |