Powered by GoogleTranslate

Inspection Detail

Inspection: 121307789 - Kriss Contracting, Inc.

Inspection Information - Office: Wilmington Area Office

 

Inspection Nr: 121307789
Report ID: 0317300
Date Opened: 10/13/1999

Site Address:
Kriss Contracting, Inc.
Northbound Sr- 1
Middletown, DE 19709

Mailing Address:
1523 Gunter Road, P.O. Box 246, Hartly, DE 19953

Union Status: NonUnion

SIC:1731

NAICS: 0 


Inspection Type: Accident

Scope: Complete

Advanced Notice: N

Ownership: Private

Safety/Health: Safety

Close Conference: 11/01/1999

Emphasis:

Case Closed: 02/24/2000


Related Activity
Type Activity Nr Safety Health
Accident 360952964
Violation Summary
Violations/Penalties Serious Willful Repeat Other Unclass Total
Initial Violations 1 1
Current Violations
Initial Penalty $375 $0 $0 $0 $0 $375
Current Penalty $0 $0 $0 $0 $0 $0
FTA Penalty $0 $0 $0 $0 $0 $0

Violation Items
# Citation ID Citaton Type Standard Cited Issuance Date Abatement Due Date Current Penalty Initial Penalty FTA Penalty Contest Latest Event Note
1. 01001A Serious 19260550 A15 II 11/11/1999 11/17/1999 $0 $375 $0 F - Formal Settlement Citation has been deleted.
2. 01001B Serious 19260028 A 11/11/1999 11/17/1999 $0 $0 $0 F - Formal Settlement Citation has been deleted.

Investigation Summary

Investigation Nr: 14228498
Event: 10/11/1999
ELECTRIC SHOCK - CONTACT WITH OVERHEAD LINE THRU LIGHT POLE

Three employees were setting a streetlighting pole using a 1989 GMC line truck. The pole had a 7.6-meter-long davit arm. An overhead power line was located about 6.1 meters from the base of the pole. As the employees were positioning the pole, the davit arm turned toward the 14-kilovolt power line and contacted it. The three employees received electric shocks. They were hospitalized for their injuries.

Keywords: OVERHEAD POWER LINE, ELECTRICAL, E GI IA, METAL POLE, STREETLIGHTING, ELECTRIC SHOCK

Investigated Inspection
# Inspection Age Sex Degree of Injury Nature of Injury Occupation
1 121307789 Hospitalized injury Electric Shock Occupation not reported
2 121307789 Hospitalized injury Electric Shock Occupation not reported
3 121307789 Hospitalized injury Electric Shock Occupation not reported
Back to Top

Thank You for Visiting Our Website

You are exiting the Department of Labor's Web server.

The Department of Labor does not endorse, takes no responsibility for, and exercises no control over the linked organization or its views, or contents, nor does it vouch for the accuracy or accessibility of the information contained on the destination server. The Department of Labor also cannot authorize the use of copyrighted materials contained in linked Web sites. Users must request such authorization from the sponsor of the linked Web site. Thank you for visiting our site. Please click the button below to continue.