Inspection Detail
Inspection: 1209683.015 - Elite Industrial Services
Inspection Information - Office: Baton Rouge Area Office
Site Address:
Elite Industrial Services
4200 Highway 190 West
Deridder, LA 70634
Mailing Address:
1929 Lake Charles Hwy., Deridder, LA 70634
Union Status: NonUnion
SIC:
NAICS: 238990/All Other Specialty Trade Contractors
Inspection Type: Fat/Cat
Scope: Partial
Advanced Notice: N
Ownership: Private
Safety/Health: Safety
Close Conference: 08/03/2017
Emphasis:
Case Closed: 08/03/2017
Type | Activity Nr | Safety | Health |
---|---|---|---|
Inspection | 1210358 | Yes |
Investigation Summary
At 11:15 a.m. on February 8, 2017, three employees were climbing down from an elevated pipe rack. As they were climbing down, the stainless steel Foul Condensate tank exploded, striking the employees and tossing their bodies 200 yards from the explosion. All three employees were killed.
Keywords: Elevated Work Platform, Explosion, Tank
# | Inspection | Age | Sex | Degree of Injury | Nature of Injury | Occupation |
---|---|---|---|---|---|---|
1 | 1209683.015 | 33 | M | Fatality | Welders and cutters | |
2 | 1209683.015 | 41 | M | Fatality | Plumber, pipefitter and steamfiter apprentices | |
3 | 1209683.015 | 42 | M | Fatality | Welders and cutters |