Powered by GoogleTranslate

Inspection Detail

Case Status: CLOSED

Inspection: 1208280.015 - Xytex Cryo International, Ltd.

Inspection Information - Office: Atlanta East Area Office

 

Inspection Nr: 1208280.015
Report ID: 0418100
Date Opened: 02/06/2017

Site Address:
Xytex Cryo International, Ltd.
1100 Emmett Street
Augusta, GA 30904

Mailing Address:
1100 Emmett Street, Augusta, GA 30904

Union Status: NonUnion

SIC:

NAICS: 621991/Blood and Organ Banks


Inspection Type: Referral

Scope: Partial

Advanced Notice: N

Ownership: Private

Safety/Health: Health

Close Conference: 02/06/2017

Emphasis:

Case Closed: 01/16/2018


Related Activity
Type Activity Nr Safety Health
Referral 1179960 Yes
Inspection 1208263 Yes
Inspection 1210711 Yes
Inspection 1210683 Yes
Case Status: CLOSED
Violation Summary
Violations/Penalties Serious Willful Repeat Other Unclass Total
Initial Violations 2 2
Current Violations 2 2
Initial Penalty $13,943 $0 $0 $0 $0 $13,943
Current Penalty $9,760 $0 $0 $0 $0 $9,760
FTA Penalty $0 $0 $0 $0 $0 $0

Violation Items
# Citation ID Citaton Type Standard Cited Issuance Date Abatement Due Date Current Penalty Initial Penalty FTA Penalty Contest Latest Event Note
1. 01001A Serious 19100132 D01 I 07/31/2017 09/15/2017 $5,324 $7,605 $0 I - Informal Settlement  
2. 01001B Serious 19100132 F01 I 07/31/2017 09/15/2017 $0 $0 $0 I - Informal Settlement  
3. 01001C Serious 19100133 A01 07/31/2017 09/15/2017 $0 $0 $0 I - Informal Settlement  
4. 01002 Serious 19101200 H01 07/31/2017 08/17/2017 $4,437 $6,338 $0 I - Informal Settlement  

Investigation Summary

Investigation Nr: 97101.015
Event: 02/05/2017
Employee is exposed to liquid nitrogen and suffers multiple

At 5:30 p.m. on February 5, 2017, an employee was responding to an emergency alarm. As he entered a space that was oxygen deficient, he was knocked unconscious. The employee was recued from the space and was hospitalized, where he received treatment for having been exposed to an oxygen deficient atmosphere, as well as hypothermia and frostbite. His injuries resulted in amputation of an unspecified extremities. The incident investigation revealed that the space contained liquid nitrogen.

Keywords: Amputation, Asphyxiated, Emergency Response, Oxygen Deficiency, Pressure Vessel, Toxic Atmosphere

Investigated Inspection
# Inspection Age Sex Degree of Injury Nature of Injury Occupation
1 1208280.015 65 F Hospitalized injury Managers and administrators, n.e.c
Back to Top

Thank You for Visiting Our Website

You are exiting the Department of Labor's Web server.

The Department of Labor does not endorse, takes no responsibility for, and exercises no control over the linked organization or its views, or contents, nor does it vouch for the accuracy or accessibility of the information contained on the destination server. The Department of Labor also cannot authorize the use of copyrighted materials contained in linked Web sites. Users must request such authorization from the sponsor of the linked Web site. Thank you for visiting our site. Please click the button below to continue.