Inspection Detail
Inspection: 120337266 - Steve P. Rados, Inc.
Inspection Information - Office: American Canyon District Office
Site Address:
Steve P. Rados, Inc.
Navy Base Off Nichols Rd.
Bay Point, CA 94596
Mailing Address:
2002 E. Mcfadden Ave., Suite 200, Santa Ana, CA 92735
Union Status: Union
SIC:1794
NAICS: 221310/Water Supply and Irrigation Systems
Inspection Type: Accident
Scope: Partial
Advanced Notice: N
Ownership: Private
Safety/Health: Safety
Close Conference: 01/23/2003
Emphasis: S:Construction (Cship)
Case Closed: 02/04/2003
| Type | Activity Nr | Safety | Health |
|---|---|---|---|
| Accident | 361734064 |
Investigation Summary
On December 7, 2002, Employee #1 sustained a punctured right testicle after being struck by a piece of metal when trying to remove a loader tooth. Employee #1 was hospitalized for four days.
Keywords: LOADER/BACKHOE, STRUCK BY, PUNCTURE
| # | Inspection | Age | Sex | Degree of Injury | Nature of Injury | Occupation |
|---|---|---|---|---|---|---|
| 1 | 120337266 | Hospitalized injury | Puncture | Miscellaneous precision workers, n.e.c. |
Translate